Advertisement

5-PLUMBING CONNECTION

PLUMBING CONNECTION
IMPORTANT:
The connections depend on the type of hydraulic kit installed and on the type of System Configuration.
IMPORTANT!
If installation of the product involves interaction with another, pre-existing system complete with heating
equipment (gas boiler, methane boiler, diesel boiler, etc.), contact qualified personnel, who subsequently will be
responsible for conformity of the system in compliance with the applicable law in force.
The Company declines all responsibility for damage to persons or things in the event of failed or incorrect operation,
if the aforementioned warnings are not complied with.
IMPORTANT!!!
FLUSH THE ENTIRE SYSTEM BEFORE CONNECTING THE BOILER IN ORDER TO REMOVE RESIDUES AND DEPOSITS.
Always install gate valves upstream from the boiler so as to disconnect it from the plumbing system should it be
necessary to move it, or when it requires routine and/or special maintenance.
Connect the boiler using hoses so that the boiler is not too strictly connected to the system, and to allow slight
movements.
HYDRAULIC KIT
The boilers must be connected to an optional hydraulic kit with or without domestic water production.
CLEANING THE SYSTEM
Install suitable shutters to cut off the tubes from the heating system.
To protect the heating system from being damaged by corrosion, incrustation or smoke deposits, it is extremely important, before the
appliance is installed, that it be washed according to the UNI 8065 standard (water treatment of thermal systems for civil use) with
appropriate products.
As standard, RED supplied the product FERNOX PROTECTOR F1 with the product.
This provides long term protection against corrosion and calcium build-up for the heating appliance. It prevents the corrosion of the metal
parts of the appliance, i.e. the ferrous metals, copper and copper and aluminium alloys. It also reduces the noise produced by the boiler.
Refer to the instructions on the product. Cleaning should be performed by a qualified technician.
We also recommend the use of FERNOX CLEANER F3 and LEAK SEALER F4, available from our authorised distribution centres.
FERNOX F3 is a neutral product for rapid and efficient cleaning of heating appliances. It has been designed to eliminate residue, oily
deposits and incrustations from existing appliances of all ages. It can help restore the heating efficiency of the boiler and reduce the noise
it generates.
FERNOX F4 is intended to be used with all heating appliances to seal micro fractures that cause small and inaccessible leaks.
Attention: Failure to clean the heating system and to add a suitable inhibitor will void the warranty of the equipment
and other accessories such as for example pumps and valves.
Technical Dept. - All rights reserved - Reproduction is prohibited