Clearances To Combustibles - Quadra-Fire VOYAGEUR-MBK Installation Manual

Voyageur wood insert automatic combustion control (acc)
Hide thumbs Also See for VOYAGEUR-MBK:
Table of Contents

Advertisement

VOYAGEUR Insert ACC
B. Clearances to Combustibles
TOP TRIM (3/4" max)
31-1/4
794mm
USA 18-3/4
CANADA
22-3/4 (578mm)
If trim measurement is over 3/4 in (19mm)
NOTE:
in depth use mantle or side clearances to
combustibles.
47-3/16
1199mm
See next page for thermal protection
In Canada a full length 6 inch (152mm) S635 flue liner required as per ULC S628.
In USA a minimum 5 ft length (1.82m), 6 inch (152mm) diameter flue liner is required as per UL 1482.
WARNING
Fire Risk.
Comply with all minimum clearances to
combustibles as specified.
Failure to comply may cause house fire.
10
21-1/4
540mm
HEARTH
EXTENSION
12in max
MANTEL
USA 17-7/16
CANADA 19-7/16 (494mm)
HEARTH EXTENSION
requirements
United States and Canada (UL and ULC)
40-3/16
1021mm
Minimum Opening Dimensions
A
Height
Front Width (Steel
Surround)
B
Front Width (Cast
Surround)
C
Back Width
Depth (Steel Surround)
D
Depth (Cast Surround)
NOTE: Minimum opening dimensions include a 1/4"
(6mm) clearance around unit.
NOTE: Keep Ashlip
Clear of Ashes
NOTE: Hearth Rug may be used in Suggested Area
NOTE: Clearances may only be reduced by means
approved by the regulatory authority having
jurisdiction
7063-513I
A
D
C
B
Inches
22-3/8
33-1/4
33-1/8
19-7/8
18-1/2
18-3/8
August 13, 2018
Millimeters
568
845
841
499
470
467