VOYAGEUR Insert ACC
B. Clearances to Combustibles
TOP TRIM (3/4" max)
31-1/4
794mm
USA 18-3/4
CANADA
22-3/4 (578mm)
If trim measurement is over 3/4 in (19mm)
NOTE:
in depth use mantle or side clearances to
combustibles.
47-3/16
1199mm
See next page for thermal protection
In Canada a full length 6 inch (152mm) S635 flue liner required as per ULC S628.
In USA a minimum 5 ft length (1.82m), 6 inch (152mm) diameter flue liner is required as per UL 1482.
WARNING
Fire Risk.
•
Comply with all minimum clearances to
combustibles as specified.
•
Failure to comply may cause house fire.
10
21-1/4
540mm
HEARTH
EXTENSION
12in max
MANTEL
USA 17-7/16
CANADA 19-7/16 (494mm)
HEARTH EXTENSION
requirements
United States and Canada (UL and ULC)
40-3/16
1021mm
Minimum Opening Dimensions
A
Height
Front Width (Steel
Surround)
B
Front Width (Cast
Surround)
C
Back Width
Depth (Steel Surround)
D
Depth (Cast Surround)
NOTE: Minimum opening dimensions include a 1/4"
(6mm) clearance around unit.
NOTE: Keep Ashlip
Clear of Ashes
NOTE: Hearth Rug may be used in Suggested Area
NOTE: Clearances may only be reduced by means
approved by the regulatory authority having
jurisdiction
7063-513I
A
D
C
B
Inches
22-3/8
33-1/4
33-1/8
19-7/8
18-1/2
18-3/8
August 13, 2018
Millimeters
568
845
841
499
470
467