REVERSE OVERRIDE /
MODE BUTTON
Function Test
Use a multimeter to test for continuity when pressing the
Reverse Override / Mode button.
Reverse Override / Mode Button Test
B
FREE
PUSH
Push the Reverse Override / Mode button. There should be
continuity between pins B and C.
B
C
If the test fails, replace the LH control assembly.
HEAD LAMP SWITCH
Function Test
Use a multimeter to test for continuity with the 3 head lamp
control outputs (OFF / LOW / HIGH) in the LH control
assembly.
C
OFF
LOW
HIGH
There should be no continuity on any pin when the headlamp
switch is in the OFF position.
Move the switch to LOW. There should be continuity between
pins D and F.
Move the switch to HIGH. There should be continuity between
pins D and E.
If any of the tests fail, replace the LH control assembly.