Oce VarioPrint 2045-65 DC Job Manual page 92

Hide thumbs Also See for VarioPrint 2045-65 DC:
Table of Contents

Advertisement

Safety Data Sheet Océ VarioPrint 2065 DC
PRODUCT SAFETY DATA SHEET
Océ-USA, Inc.
Model
Description
Process speed
Dimensions
Weight
Voltage
Frequency
Current-rated
Building fuse
Power consumption, stand-by
Power consumption, operation
EPA
E
NERGY
* Power consumption, auto off
* Power consumption,
Mains connection
Safety class
Protection class
Sound pressure level
(at operator position)
Sound power level
Radio interference
Radiation
Heat emission
Ozone emission
Dust concentration
Room volume
Room ventilation
Use simulation at random
operation
Consumables
Additional safety information
Copyright © 2003 Océ-Technologies B.V., Venlo, NL
The content of this safety data sheet is subject to the disclaimer of liability (see
'Disclaimer') of this manual.
92
Océ VarioPrint 2045-65 DC Job manual
Océ VarioPrint 2065 DC
Electrostatic digital copier, console model, plain paper, organic photoconductive belt,
powder toner, automatic duplexing.
62 A4 copies/min or 30 A3 copies/min
Width
Depth
Height
®
S
TAR
low power
Cable with plug
I
IP 20
Standby
33 dB(A)
45 dB(A)
Complies with Directive 89/336/EEC and FCC rules and regulations, part 15 Class A.
Below the Threshold Limit Values for UV, Visible and IR radiation (TLV list of ACGIH)
Standby 380 W ; in operation 1,8 kW
0,01 mg/min at continuous operation
0,02 mg/m
Recommendation: min. 30 m
Recommendation: min. 15 m
For heat evacuation extra ventilation may be necessary.
Room volume and ventilation as recommended
Daily copy volume (much more than average)
Total worktime
Ozone concentrations:
- Time weighted average
- Peak
Threshold Limit Value/Occupational Exposure Limit
(Time Weighted Average) for ozone
Odour Perception Limit for ozone
Océ Master (Océ Material Safety Data Sheet E-193)
Océ F11 Toner (Océ Material Safety Data Sheet E-212)
Océ Copying Materials
This apparatus is suitable for processing recycling paper which complies with the
requirements of EN 12281.
The ozone filter does not have to be replaced for keeping the ozone concentration in the
workplace below 0,04 mg/m
Listed according to standard UL 1950 and CAN/CSA-C22.2 No.950
1645 mm
900 mm (including wall spacers)
1275 mm
404 kg
120 V
208 V
60 Hz
60 Hz
15 A
9 A
20 A
16 A
380 W
1,8 kW
5 W
200 W (recovery time <10 s)
(IEC 536) Protective earth connection
(IEC 529)
3
at continuous operation
3
3
/h (natural ventilation)
3
(the life of the filter equals that of the apparatus).
LISTED 927F
INFORMATION
TECHNOLOGY
EQUIPMENT
E 69871
Number
Date
240 V
60 Hz
8 A
16 A
In operation
mainbody 56 dB(A);
incl. optionals 62 dB(A); impulse ! L
mainbody 73 dB(A); incl. optionals 74 dB(A)
7500 A4
8 h
3
0,001 mg/m
3
0,003 mg/m
3
0,2 mg/m
3
0,04 mg/m
EPA
E
NERGY
E-774-a-US
September 2003
= 3 dB(A)
i
(0.0005 ppm)
(0.0015 ppm)
(0,1 ppm)
(0,02 ppm)
®
S
TAR

Advertisement