3. Release the rivet holding the air bell to the outer tub.
NOTE: Seal air connecting tube to air bell and air
bell to sump hose using waterproof glue.
DO NOT plug air connecting tube opening.

Removing the tub assembly:

1. Disconnect the washer from the electrical supply
and the hot and cold water hoses.
2. Remove the top panel, console, rear access panel
and the front panel.
3. Disconnect the advance rinsing technology hose
from the bellows, the detergent outlet and siphon
break hoses from the outer tub.
4. Remove the drain pump and disconnect the drain
sump from the tub.
5. If you are going to replace the front half of the outer
tub remove the bellows and the weight ring.
6. Remove the small hose from the air bell.
7. Remove the large pulley, drive motor and speed
control board assembly.
8. Disconnect the bearing ground wire.
9. Remove the top pins from shock absorbers and push
the shock absorbers against the cabinet.
10. Place something down to protect the floor, carefully
turn the washer on it's face and release the springs.