EVAPORATOR TEMPERATURE / SEALED SYSTEM LOW-SIDE PRESSURE CORRELATION
NOTE: The temperature/pressure table at right
is for reference only. A unit's temperature/pres-
sure correlation may differ from those listed due
to: variations in evaporator thermistor location,
set-points, where the sealed system is in the
refrigeration cycle, etc.
If a unit is experiencing temperature problems,
it is recommended to reference the General
Troubleshooting guide and follow any "Pointers"
that may appear in the first column. After all
mechanical and electrical components have
been ruled out, sealed system pressures can
be checked by applying solder-on process
valves and referencing the preceding page. Do
NOT use bolt-on process valves as they are
prone to leak.
This table should only be used as a last quick
check before entering the sealed system.
3
Series
(700-
BASE)
8-17
Troubleshooting Guides
Temp °F
Pressure
-30
10" Vac
-25
7" Vac
-20
4" Vac
-15
0" Vac
-10
2 Psi
-5
4 Psi
0
7 Psi
5
9 Psi
10
12 Psi
15
15 Psi
20
18 Psi
25
22 Psi
30
26 Psi
35
30 Psi
40
35 Psi
45
40 Psi
50
45 Psi
55
51 Psi
60
57 Psi
65
64 Psi
70
71 Psi
75
78 Psi
#3758424 - Revision B - December, 2005