Technical Data

Model 700BF/I-3

CHARGE (R-134a Refrigerant)
NOTE: Always check serial tag for exact charge
NORMAL OPERATING PRESSURES
COMPRESSOR
NOTE: Always check current parts price list for possible substitutions.
DEFROST METHOD
DEFROST TERMINATOR
DEFROST HEATER
DRAIN TUBE HEATER
FILL TUBE HEATER
WATER VALVE
THERMISTORS
(Evap & Compartment)
#3758424 - Revision B - December, 2005
Integrated
(700-
Service Part No.
Mfg. Model No.
Original/Service Compressor Amps
Original/Service Compressor BTU/H
Cut-Out Temp.
Resistance/Ohms
Resistance/Ohms
Resistance/Ohms
Resistance/Ohms (Inductive)
Resistance/Ohms at 32°F / 0°C
9-4
3
Series
BASE)
FREEZER
Low Side
3" vacuum to 2 psi
High Side
90 psi to 120 psi
Manufacturer
"Adaptive Defrost"
Defrost intervals and
duration vary by unit use.
5 minute compressor
delay after each defrost.
Cut-In Temp.
30°F / -1°C
70°F / 21°C
Watts
Amps
Watts
Mili-Amps
50 - 60 mA
1700 - 2100
Watts
Amps
30 - 40 mA
2300 - 2900
Watts
Amps
30000 - 33000
6 oz.
4201860
Embraco
FGS70HA
1.2 / 1.2
710 / 715
490
4.1 - 4.5
25 - 29
7
4.2
50
0.42
160