Valve History - Hellenbrand ProMate Series Owner's Manual

Hellenbrand promate series twin alt manual
Table of Contents

Advertisement

MAX FLOW
6
12.7
DAY
GAL
"1"
0 DAYS
12:35 PM
0.00
GAL
A - B
ALT + FIRST
TTT
CCC
CYC
VVV
RETURN TO NORMAL MODE
STEP 1VH
AC SOFTWARE VERSION
101.03
STEP 2VH
970
TOTAL DAYS
STEP 3VH
TOTAL REGENS
235
STEP 4VH
TOTAL GALLONS
175
GAL
x1K
STEP 5VH
ERROR LOG
XXXX
1- - -
14
STEP 5D – Flow rate, maximum of each of last seven days: The maximum flow rate in gallons
STEP 5D
per minute that occurred in each of the last seven days will be displayed. Press  arrow to dis-
play maximum flow rate today = 0, yesterday = 1. This display will equal zero if a water meter is
not installed. Resettable by pressing  &  arrows for 5 seconds. Press REGEN to return to
the previous step.
STEP 6D – Diagnostic 4T– Tank Transfer History
STEP 6D
Up and down arrows scroll through each of the last 10 tank transfers
"1" = Transfer Number (10 Transfers Max)
"A" = Tank Transferring
"3" = Days Ago of Transfer (99 Days Max)
"0.00" = Gallons Used at Time of Transfer Display, viewed in 1.0T Mode only.
STEP 7D – MAV Drive History – Not displayed if MAV set to off.
STEP 7D
• First - Average of 1st three drive times of MAV in that direction
• Last - Last drive time measured for that MAV in that direction
• Ave - Average drive time measured for MAV in that direction
• TTT - Drive time (1424 = 14.24 seconds)
• CCC - Total number of cycles for that MAV
• VVV - Relative drive voltage
MAV drives piston "in" is designated by (-) sign.
MAV drives piston "out" is designated by (+) sign.
Any time MAV is rebuilt or replaced, reset diagnostics to reflect new drive characteristics.
STEP 1VH – Press  and  simultaneously until display changes, release and press  and 
again simultaneously and release. If screen in step 1VH does not appear in 5 seconds the lock on
the valve is activated.
STEP 2VH – Days, total since start-up: This display shows the total days since startup. Press
the NEXT button to go to Step 3VH. Press REGEN to return to previous step.
STEP 3VH – Regenerations, total number since start-up: This display shows the total number
of regenerations that have occurred since startup. Press the NEXT button to go to Step 4VH.
Press REGEN to return to previous step.
STEP 4VH – Volume, total used since start-up: This display shows the total gallons treated
since startup. This display will equal zero if a water meter is not installed. Press NEXT button to
go to Step 5VH. Press REGEN to return to previous step.
STEP 5VH – Error Log history: up to 10 errors. Press  and  buttons to view each recorded
error. If no errors have occurred " – – – –" is displayed. With STALL ERRORS 102, 107, 117 in
right upper corner of display indicates motor position at time of error detection. Press NEXT to exit

valve history.

vAlve hiSTOrY
(Can not be reset)