SET
6:35
SET TIME
6:35
SET TIME
RETURN TO ROTATING DISPLAY
WATER HARDNESS
20
SET
DAYS BETWEEN REGEN
14
SET
REGEN IMMEDIATE
ON ZERO
RETURN TO ROTATING DISPLAY
8
Step 1
Step 1 - Press SET CLOCK.
Step 2 - Current Time (hour): Set the hour of the day using  or  buttons. AM/PM
toggles after 12. Press NEXT to go to step 3.
PM
Step 2
Step 3 - Current Time (minutes): Set the minutes of day using  or  buttons. Press
NEXT to exit Set Clock. Press REGEN to return to previous step.
Power Loss - Lithium battery on circuit board provides up to 2 years of time clock backup
during power outages. If the power is out when battery is depleted, only time of day needs
to be reset, all other values are stored in non-volatile memory. When time of day is flash-
ing, replace lithium coin type 2032 battery.
PM
Step 3
Battery back-up feature will be activated after 24 hours of power.
Do not forget to reset for daylight savings time.
Figure 9
inSTAller DiSPlAYS/SeTTinGS
Step 1I
Step 1I - Press NEXT and  simultaneously for 3 seconds.
Step 2I - Hardness: Set the amount of total compensated hardness in grains (hard-
ness as calcium carbonate) per gallon using  or  buttons. The factory setting is
20 with value ranges from 1 to 150 in 1 grain increments. Note: The grains per gallon
Step 2I
should be increased if soluble iron needs to be reduced.
for each ppm of iron present. If this display shows nA -, then system is set-up in "filter"
GR
mode or "AUTO" is not selected in softener system setup. (See page 32). Press
NEXT to go to Step 3. Press REGEN to exit Installer Displays/Settings.
Step 3I - Day Override: This sets the number of days between regenerations. If
value set to "oFF" regeneration initiation is based solely on gallons used. If value is
set as a number (allowable range from 1 to 28) a regeneration initiation will be called
Step 3I
for on that day even if sufficient number of gallons were not used to call for a regen-
eration. Set Day Override using  or  buttons. As twin alternating configuration is
soften applied for salt and water efficiency: Factory setting is Off.
• number of days between regeneration (1 to 28); or
• "oFF"
Press NEXT to go to step 4. Press REGEN to return to previous step.
Step 4I - Regeneration: This display will show REGEN IMMEDIATE, ON ZERO GAL-
Step 4I
LONS, when set for twin alternating.
Figure 10a
SeT TiMe Of DAY
=  Up Arrow
=  Down Arrow
=  Up Arrow
=  Down Arrow
Add 3 grains of hardness