Hellenbrand ProMate Series Owner's Manual page 17

Hellenbrand promate series twin alt manual
Table of Contents

Advertisement

BACKWASH
STEP 8CS
CYCLE 1
SET
REGENERANT DRAW DN
STEP 9CS
CYCLE 2
SET
BACKWASH
STEP 10CS
CYCLE 3
SET
RINSE
STEP 11CS
CYCLE 4
SET
FILL
STEP 12CS
CYCLE 5
SET
END
STEP 13CS
CYCLE 6
SET
ALT FILL TRIGGER
STEP 14CS
REGENS
OFF
SET
ALT FILL AMOUNT
STEP 15CS
15.0
LBS
SET
17
STEP 8CS – Press the  or  buttons until selection of first cycle appears in left upper corner,
in this example BACKWASH is selected. Press NEXT to go to Step 9CS. Press REGEN to
return to previous step.
STEP 9CS – Press the  or  buttons until selection of second cycle appears in left upper cor-
ner, in this example Regenerant Draw DN is selected. For a H125 control valve: prior to select-
ing DN or UP or not selecting a regenerant flow cycle, verify the correct valve body, main piston,
regenerant piston and stack are being used and the injector or injector plug(s) are in the correct
location. On Calendar Day Override on upflow brining, may select 20% or preprogram amount
for brining. Press NEXT to go to Step 10CS. Press REGEN to return to previous step.
STEP 10CS – Press the  or  buttons until selection of third cycle appears in left upper corner,
in this example BACKWASH is selected. A second backwash mode is recommended on iron
applications > 1.0 ppm. Press NEXT to go to Step 11CS. Press REGEN to return to previous
step.
STEP 11CS – Press the  or  buttons until selection of fourth cycle appears in left upper
corner, in this example RINSE is selected. Press NEXT to go to Step 12CS. Press REGEN to
return to previous step.
STEP 12CS – Press the  or  buttons until selection of fifth cycle appears in upper left corner.
Press NEXT to go to Step 13CS. Press REGEN to return to previous step.
STEP 13CS – Press the  or  button until last regeneration cycle; END appears (up to 9
regeneration modes are possible). End must be selected as last cycle. Press NEXT to go to
Step 14CS.
STEP 14CS – Press the  or  button to select number of standard regenerations which would
trigger one alternate brine fill amount. Range: 1-99. Factory setting is Off. Press NEXT to go
to Step 15CS.
STEP 15CS – Select amount of salt to be used when alternate regeneration requested. This
screen is not displayed if off is selected in previous step. Softener Range 0.1–200 lbs. Filter
Range 0.05–20.0 Gallons. Press NEXT to end cycle sequence.