Valve History - Hellenbrand H-125 Series Owner's Manual

Water conditioning system
Hide thumbs Also See for H-125 Series:
Table of Contents

Advertisement

USAGE HISTORY
108
1
DAY
GAL
MAX FLOW
6
12.7
DAY
GAL
ALT + FIRST
TTT
CCC
CYC
VVV
RETURN TO NORMAL MODE
STEP 1VH
STEP 2VH
970
TOTAL DAYS
STEP 3VH
TOTAL REGENS
235
STEP 4VH
TOTAL GALLONS
175
GAL
x1K
STEP 5VH
ERROR LOG
XXXX
1- - -
RETURN TO ROTATING DISPLAY
14
STEP 5D – Volume of water used, 63-day usage history: This display shows day 0 (for today)
STEP 5D
and 1 (for yesterday) will show day 2 (which would be the day before yesterday) and flashes
the volume of water treated on that day. Continue to press the  button to show the volume of
water treated for the last 63 days. If a regeneration occurred on the day the "letter R" will also be
displayed. This display will show dashes if a water meter is not installed. Press the NEXT button
at any time to go to Step 6 D. Press REGEN to return to the previous step.
STEP 6D – Flow rate, maximum of each of last seven days: The maximum flow rate in gallons
STEP 6D
per minute that occurred in each of the last seven days will be displayed. Press  arrow to
display maximum flow rate today = 0, yesterday = 1. This display will equal zero if a water meter
is not installed. Press the NEXT button to go to Step 7D. Press REGEN to return to the previous
step.
STEP 7D – MAV Drive History – Not displayed if MAV set to off.
• First - Average of 1st three drive times of MAV in that direction
STEP 7D
• Last - Last drive time measured for that MAV in that direction
• Ave - Average drive time measured for MAV in that direction
• TTT - Drive time (1424 = 14.24 seconds)
• CCC - Total number of cycles for that MAV
• VVV - Relative drive voltage
MAV drives piston "in" is designated by (-) sign.
MAV drives piston "out" is designated by (+) sign.
Any time MAV is rebuilt or replaced, reset diagnostics to reflect new drive characteristics.
STEP 1VH – Press  and  simultaneously for three seconds and release, then press  and 
simultaneously and release. If screen in step 2VH does not appear in 5 seconds the lock on the
valve is activated.
STEP 2VH – Days, total since start-up: This display shows the total days since startup. Press
the NEXT button to go to Step 3VH. Press REGEN to return to previous step.
STEP 3VH – Regenerations, total number since start-up: This display shows the total number
of regenerations that have occurred since startup. Press the NEXT button to go to Step 4VH.
Press REGEN to return to previous step.
STEP 4 VH – Volume, total used since start-up: This display shows the total gallons treated
since startup. This display will equal zero if a water meter is not installed. Press NEXT button to
exit Valve History. Press REGEN to return to
previous step.
STEP 5 VH – Error Log history: up to 10 errors. Press  and  buttons to view each recorded
error. If no errors have occurred " – – – –" is displayed. With STALL ERRORS 102, 107, 117, right
upper corner of display indicates piston position at time of stall. Press NEXT to exit valve history.

VALVE HISTORY

(Can not be reset)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents