Hellenbrand ProMate Series Owner's Manual page 10

Hellenbrand promate series twin alt manual
Table of Contents

Advertisement

SOFTENING TIME
120:00
SET
MIN
BACKWASH TIME
8:00
SET
MIN
DRAW TIME
60:00
SET
MIN
BACKWASH TIME
8:00
SET
MIN
RINSE TIME
4:00
SET
MIN
GRAIN OF CAPACITY
22.9
SET
x1K
RESERVE CALCULATOR
AUTO
SET
Figure 12a
10
STEP 4 S – Select the time for the second cycle (which in this example is SOFTENING)
Step 4S
using  or  button. Press NEXT to go to Step 5S. Press REGEN to return to the previous
step.
Step 5S
STEP 5 S – Select the time for the third cycle (which in this example is BACKWASH) using
the  or  button. Press NEXT to go to Step 6S. Press REGEN to return to the previous
step.
STEP 6 S – Select the time for the fourth cycle (which in this example is BRINE DRAW)
Step 6S
using the  or  button. Press NEXT to go to Step 7S. Press REGEN to return to the previ-
ous step.
STEP 7 S – Select the time for the fifth cycle (which in this example is SECOND BACK-
Step 7S
WASH) using the  or  button. Press NEXT to go to Step 8S. Press REGEN to return to the
previous step.
STEP 8 S – Select the time for the sixth cycle (which in this example is RINSE) using the
Step 8S
 or  button. Press NEXT to go to Step 9S. Press REGEN to return to the previous step.
STEP 9 S - Set Grain Capacity using the  or  button. The ion exchange capacity is in
Step 9S
grains of hardness as calcium carbonate for the system based on the pounds of salt that will
be used. The allowable grains capacity range varies from 5,000 to 3,000,000 grains. The
increment increase is 500 for the range from 5000 to 30,000; 1000 for the range of 30,000
to 100,000; and 2000 for the range of 100,000 to 3,000,000. Grains capacity is affected by
the fill time. The grains capacity for the selected lbs. salting should be confirmed by testing.
The capacity and hardness levels entered are used to automatically calculate gallon capacity
when set to AUTO. Factory setting is the capacity of the softener at low salting. See
Page 38. Press NEXT to go to Step 10S. Press REGEN to return to previous step.
STEP 10 S – Set Gallons Capacity using  or  button. If value is set to:
• "AUTO" gallon capacity will be automatically calculated.
Step 10S
• "oFF" regeneration will be based solely on the day override set (see Installer Display/Set-
tings Step 3, page 8 / proportional brining will not function if OFF selected); or
• as a number of gallons (allowable range 20 to 1,500,000) regeneration will be based on
the value specified. For applications that require 1 gpg soft water at peak flows near end of
service run, may need to adjust capacity to include safety factor.
Increment increase is 20 for the range 20 to 2000, 100 for the range of 2000 to 10,000 and
500 for the range of 10,000 to 50,000 and 2000 for range of 50,000 to 1,500,000.
If "oFF" or a number is used, hardness cannot be set in Installer Displays/Settings Step 2,
page 8. Factory Setting is AUTO. Press NEXT to go to Step 11 S. Press REGEN to return
to previous step.