Softener Setup - Hellenbrand ProMate Series Owner's Manual

Hellenbrand promate series twin alt manual
Table of Contents

Advertisement

Manual regeneration
To initiate a manual transfer of tank, press and hold REGEN button. This will initiate a
regeneration on the tank previously in service and put standby tank into service.
Normally it is not recommended to adjust the lengths of the cycle times. However, certain water conditions may
dictate adjustments. This should only be done from the recommendation of a water conditioning professional.
The following chart shows the upper and lower limits of each cycle.
Cycle Options
Fill
Softening (Service)
Backwash
Regenerant Draw DN Time
Rinse-Fast
Regenerant Draw UP Time
SOFTENING
TYPE
SET
FILL
6.0
LBS
SET
9
CYCle TiMe ADJuSTMenTS
Units
Minutes
Minutes
Minutes
Minutes
Minutes

SOfTener SeTuP

=  Up Arrow
Step 1S
STEP 1S – Press NEXT and  simultaneously for 3 seconds. If screen in Step 2S does
not appear in 5 seconds the lock on the valve is activated.
Step 2S
STEP 2S – Select between softening or filtering. A flashing "SOFTENING" or
"FILTERING" will appear. Choose SOFTENING using  or  button. Factory setting is
Softening. Press NEXT to go to Step 3S. Press REGEN to exit Softener System Setup.
Step 3S
STEP 3S – Select the time for the first cycle (which in this example is FILL, setting is
changed by lbs. of salt entered) using the  or  button. Factory setting is Low Salting,
See page 38. Press NEXT to go to Step 4S. Press REGEN to return to previous step.
Lower/Upper Limit
Lbs.
0.1 to 200
1 to 480
1 to 120
1 to 180
1 to 120
1 to 180
=  Down Arrow
A
CAPACITY REMAINING
320
Factory Setting
See Page 38
120
8
60
4
60
GAL

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents