APPENDIX 5 PIN CONFIGURATION
* The D-Sub connector shown above is optional
.
PIN
FUNCTION
1~4
ALARM INPUT
5
GND
EXTERNAL ALARM
6
COM
EXTERNAL ALARM
7
NO
8
RS485-A
9
RS485-B
10~11
GND
Siren:
When the DVR is triggered by alarm or motion, the
COM connects with NO and the siren strobe will
start wailing and flashing
Magnetic Contact:
When the magnetic contact is opened, the alarm
will be triggered and recording will begin.
Connect ALARM INPUT (PIN1 – 4) and GND (PIN5) connector with wires.
Once an alarm is triggered, the DVR will start recording and the buzzer
will be on.
PIN
Alarm
Corresponding video channel
PIN 1
1
CH1
PIN 2
2
CH2
PIN 3
3
CH3
PIN 4
4
CH4
GROUND
Under the normal operation, COM disconnects with NO. But when any
alarm is triggered, COM connects with NO.
Attention: The voltage restriction is under DC24V 1A.
Under the normal operation, COM disconnects with NO. But when any
alarm is triggered, COM connects with NO.
Attention: The voltage restriction is under DC24V 1A.
For Selected Models Only
For Selected Models Only
GROUND
51
APPENDIX 5 PIN CONFIGURATION
DESCRIPTION