Sign In
Upload
Manuals
Brands
Agilent Technologies Manuals
Multimeter
34410A
Agilent Technologies 34410A Manuals
Manuals and User Guides for Agilent Technologies 34410A. We have
4
Agilent Technologies 34410A manuals available for free PDF download: User Manual, Service Manual, Datasheet
Agilent Technologies 34410A User Manual (152 pages)
6 1/2 Digit Multimeter
Brand:
Agilent Technologies
| Category:
Multimeter
| Size: 5.05 MB
Table of Contents
1 Quick Start
13
Restricted Rights Legend
2
Safety Information
3
In this Guide
11
Table of Contents
13
Quick Start
13
Basic Multimeter Operations
14
Preparing the Multimeter for Use
14
Using the Front Panel (34410A/11A)
15
Front-Panel Keys
15
Front-Panel Display Shortcuts
16
Making Basic Measurements (34410A/11A)
17
To Measure DC Voltage
18
To Measure AC Voltage
18
To Measure DC Current
19
To Measure AC Current
19
To Make a 2-Wire Resistance Measurement
20
To Make a 4-Wire Resistance Measurement
20
To Measure Frequency
21
To Measure Period
21
To Measure Capacitance
22
To Make a 2-Wire Temperature Measurement
23
To Make a 4-Wire Temperature Measurement
23
To Test Continuity
24
To Check Diodes
24
Other Basics of Operation
25
If the Multimeter Does Not Turn on
25
To Replace the Power-Line Fuse (34410A/11A)
26
To Adjust the Carrying Handle
27
To Rack Mount the Multimeter (34410A/11A)
28
Quick Start/Other Basics of Operation
29
Features and Functions
35
SCPI Commands
37
Front Panel Features (34410A/11A)
38
Front Panel Display
38
Displayed Messages
38
Self-Guiding Menus
38
Annunciators
40
Second Display Options
41
Turning the Display off
41
Front-Panel Display Shortcuts
42
Front Panel Alphanumeric Character Entry
43
Front Panel Measurement Configuration Menus
44
Configuring DC Voltage and DC Current Measurements
44
Configuring AC Voltage and Current Measurements
45
Configuring Resistance Measurements
45
Configuring Frequency and Period Measurements
46
Configuring Temperature Measurements
46
Configuring Capacitance Measurements
47
Continuity and Diode Tests
47
Advanced Configuration Options
48
Multimeter State Storage
48
Accessing Reading Memory
49
Front/Rear Input Terminal Switching (34410A/11A)
49
Multimeter Reset
50
DC Measurements
51
Integration Time and Resolution
51
DC Input Impedance
53
AC Measurements
54
AC Filter
54
Gate Time
55
Auto Zero
56
Ranging
57
Null Measurements
59
Miscellaneous Configuration Settings
60
Radix Character (34410A/11A)
60
Thousands Separator (34410A/11A)
60
Beeper (34410A/11A)
61
Math Functions
62
Db Measurements
63
Dbm Measurements
64
Using Statistics
65
Limit Testing
66
Triggering the Multimeter
67
Selecting a Trigger Source
67
Auto Triggering (34410A/11A)
68
Single Triggering (34410A/11A)
68
Reading Hold (34410A/11A)
69
Immediate Triggering
69
Software (Bus) Triggering
70
Internal (Level) Triggering (34411A/L4411A)
70
Number of Samples Per Trigger
71
Number of Pre-Trigger Samples (34411A/L4411A)
71
Trigger Delay
72
Automatic Trigger Delay
73
External Triggering
75
Trigger Slope
77
Data Logging
78
System-Related Operations
82
Self-Test
82
Error Conditions
83
Reading the Error Queue
84
NISPOM Memory Sanitization
84
Calibration
84
Power-On and Reset State
85
3 Remote Interface Configuration
87
Configuring the GPIB Interface
89
Configuring the USB Interface
90
Configuring the LAN Interface
91
Configuring LAN Parameters
92
Dhcp
92
Auto-IP
92
IP Address
93
Subnet Mask
93
Default Gateway
94
Host Name
94
DNS Server
95
Web Password
95
Instrument Unexpectedly Goes into Remote
95
Setting up a LAN Connection from the Front Panel
96
Setting up a LAN Connection from the Remote Interface
97
Agilent 34410A/11A Web Interface
98
4 Measurement Tutorial
99
DC Measurement Considerations
101
Thermal EMF Errors
101
Loading Errors (DC Volts)
101
Noise Rejection
102
Rejecting Power-Line Noise Voltages
102
Common Mode Rejection (CMR)
102
Noise Caused by Magnetic Loops
103
Noise Caused by Ground Loops
103
Resistance Measurement Considerations
104
4-Wire Ohms Measurements
104
Removing Test Lead Resistance Errors
105
Minimizing Power Dissipation Effects
105
Errors in High Resistance Measurements
105
True RMS AC Measurements
106
True RMS Accuracy and High-Frequency Signal Content
107
Estimating High-Frequency (Out-Of-Band) Error
110
Frequency and Period Measurement Errors
112
Other Primary Measurement Functions
112
DC Current Measurements
112
Capacitance Measurements
113
Temperature Measurements
115
Probe Type Choice
115
2-Wire Vs. 4-Wire Measurements
115
Auto Zero On/Off
116
Integration
116
Offset Compensation
116
NULL Reading
116
High-Speed Measurements
117
Making High-Speed AC Measurements
117
Making High-Speed DC and Resistance Measurements
118
Other Sources of Measurement Error
119
Settling Time Effects
119
Loading Errors (Ac Volts)
119
Measurements below Full Scale
120
High-Voltage Self-Heating Errors
120
AC Current Measurement Errors (Burden Voltage)
120
Low-Level Measurement Errors
120
Common Mode Errors
122
Leakage Current Errors
122
5 Specifications
123
DC Characteristics
125
AC Characteristics
128
Frequency and Period Characteristics
130
Capacitance Characteristics
132
Temperature Characteristics
132
Additional 34411A/L4411A Specifications
133
Measurement and System Speeds
134
System Speeds
135
Data from Memory
136
General Specifications (34410A/11A)
136
General Specifications (L4411A)
137
Triggering and Memory
137
Dimensions
138
To Calculate Total Measurement Error
139
Interpreting Accuracy Specifications
141
Transfer Accuracy
141
24-Hour Accuracy
141
90-Day and 1-Year Accuracy
141
Temperature Coefficients
141
Configuring for Highest Accuracy Measurements
142
DC Voltage, DC Current, and Resistance Measurements
142
AC Voltage and AC Current Measurements
142
Frequency and Period Measurements
142
A Appendix: Firmware and Driver Updates
143
Downloading the Update Utility and Firmware
144
Downloading IVI-COM Driver Updates
147
Advertisement
Agilent Technologies 34410A User Manual (144 pages)
6 1/2 Digit Multimeter
Brand:
Agilent Technologies
| Category:
Multimeter
| Size: 6.93 MB
Table of Contents
Restricted Rights Legend
2
Safety Information
3
The Front Panel at a Glance
8
The Rear Panel at a Glance
9
The Display at a Glance
10
In this Guide
11
Table of Contents
13
Quick Start
19
To Prepare the Multimeter for Use
20
Basic Measurement Operation
21
Test Lead Connections
21
Front Panel Keys
21
Front-Panel Display Shortcuts
22
To Measure DC Voltage
23
To Measure AC Voltage
23
To Measure DC Current
24
To Measure AC Current
24
To Make a 2-Wire Resistance Measurement
25
To Make a 4-Wire Resistance Measurement
25
To Measure Frequency
26
To Measure Period
26
To Measure Capacitance
27
To Make a 2-Wire Temperature Measurement
28
To Make a 4-Wire Temperature Measurement
28
To Test Continuity
29
To Check Diodes
29
Other Basics of Operation
30
If the Multimeter Does Not Turn on
30
To Replace the Power Line Fuse
31
To Adjust the Carrying Handle
32
To Rack-Mount the Multimeter
33
Features and Functions
35
SCPI Commands
38
SCPI Language Conventions
38
SCPI Language Version
38
Front Panel Features
39
Front Panel Display
39
Displayed Messages
39
Self-Guiding Menus
39
Annunciators
41
Second Display Options
42
Turning the Display off
42
Front-Panel Display Shortcuts
43
Ranging
43
Digit Masking
43
Integration Time (Bandwidth, Gate Time)
43
Front Panel Alphanumeric Character Entry
44
Front Panel Measurement Configuration Menus
45
Configuring DC Voltage and DC Current Measurements
45
Configuring AC Voltage and Current Measurements
46
Configuring Resistance Measurements
46
Configuring Frequency and Period Measurements
47
Configuring Temperature Measurements
47
Configuring Capacitance Measurements
48
Front/Rear Input Terminal Switching
48
Advanced Configuration Options
49
Power-On State
49
Multimeter State Storage
51
Multimeter Reset
52
Measurement Time and Resolution
53
DC, Resistance and Temperature Measurements
53
AC Measurements
55
AC Filter
56
DC Input Impedance
57
Autozero
58
Ranging
59
Null Measurements
61
Features and Functions (Continued)
61
Miscellaneous Configuration Settings
62
Radix Character
62
Thousands Separator
62
Beeper
63
Math Functions
64
Dbm Measurements
65
Db Measurements
65
Using Statistics
67
Limit Testing
68
Triggering the Multimeter
69
Selecting a Trigger Source
69
Auto Triggering
70
Single Triggering
70
Reading Hold
70
Internal Triggering
71
Software (Bus ) Triggering
71
Number of Samples Per Trigger
72
Trigger Delay
72
Automatic Trigger Delay
74
External Triggering
76
Trigger Slope
77
Reading Memory
78
Data Logging
79
Features and Functions
81
System-Related Operations
83
Self-Test
83
Error Conditions
84
Calibration
84
Remote Interface Configuration
85
Remote Interface Configuration Methods
86
Configuring a GPIB Interface
87
Configuring a USB Interface
88
Configuring a LAN Interface
89
LAN Configuration Parameters
89
Assigning the LAN IP Address Using Auto-IP
90
Setting the LAN IP Address Manually
90
Setting the LAN Subnet Mask
91
Setting the LAN Default Gateway
91
Setting the LAN Host Name
92
Setting the LAN DNS Server
92
Setting a Web Password
92
34410A/34411A Web Browser Interface
93
Setting up a LAN Connection from the Front Panel
94
Setting up a LAN Connection from the Remote Interface
95
Measurement Tutorial
97
DC Measurement Considerations
99
Thermal EMF Errors
99
Loading Errors (DC Volts)
99
Noise Rejection
100
Rejecting Power-Line Noise Voltages
100
Common Mode Rejection (CMR)
100
Noise Caused by Magnetic Loops
101
Noise Caused by Ground Loops
101
Resistance Measurement Considerations
102
4-Wire Ohms Measurements
102
Removing Test Lead Resistance Errors
103
Minimizing Power Dissipation Effects
103
Errors in High Resistance Measurements
103
Measurement Tutorial (Continued)
103
True RMS AC Measurements
104
True RMS Accuracy and High-Frequency Signal Content
105
Estimating High-Frequency (Out-Of-Band) Error
107
Other Primary Measurement Functions
109
Frequency and Period Measurement Errors
109
DC Current Measurements
109
Capacitance Measurements
110
Temperature Measurements
112
Probe Type Choice
112
2-Wire Vs. 4-Wire Measurements
112
Auto Zero On/Off
113
Integration
113
Offset Compensation
113
NULL Reading
113
High-Speed Measurements
114
Making High-Speed AC Measurements
114
Making High-Speed DC and Resistance Measurements
115
Other Sources of Measurement Error
116
Settling Time Effects
116
Loading Errors (Ac Volts)
116
Measurements below Full Scale
117
High-Voltage Self-Heating Errors
117
AC Current Measurement Errors (Burden Voltage)
117
Low-Level Measurement Errors
117
Common Mode Errors
119
Leakage Current Errors
119
Specifications
121
DC Characteristics
123
AC Characteristics
126
Frequency and Period Characteristics
128
Capacitance Characteristics
130
Temperature Characteristics
130
Measurement and System Speeds
131
Data from Memory
132
General Specifications
133
Dimensions
135
To Calculate Total Measurement Error
136
Accuracy Specifications
138
Transfer Accuracy
138
24-Hour Accuracy
138
90-Day and 1-Year Accuracy
138
Temperature Coefficients
138
Configuring for Highest Accuracy Measurements
139
DC Voltage, DC Current, and Resistance Measurements
139
AC Voltage and AC Current Measurements
139
Agilent Technologies 34410A Service Manual (126 pages)
6 1/2 Digit Multimeter
Brand:
Agilent Technologies
| Category:
Multimeter
| Size: 4.37 MB
Table of Contents
Restricted Rights Legend
2
Safety Information
3
The Front Panel at a Glance
8
The Rear Panel at a Glance
9
The Display at a Glance
10
In this Guide
12
Table of Contents
13
Specifications
17
DC Characteristics
19
AC Characteristics
22
Frequency and Period Characteristics
24
Capacitance Characteristics
26
Temperature Characteristics
26
Additional 34411A Specifications
27
Operating Characteristics - Maximum Readings/Second
27
Measurement and System Speeds
28
System Speeds
29
Data from Memory
30
General Specifications
30
General Specifications (34410A/11A)
30
Dimensions
32
To Calculate Total Measurement Error
33
Interpreting Accuracy Specifications
35
Transfer Accuracy
35
24-Hour Accuracy
35
90-Day and 1-Year Accuracy
35
Temperature Coefficients
35
Configuring for Highest Accuracy Measurements
36
DC Voltage, DC Current, and Resistance Measurements
36
AC Voltage and AC Current Measurements
36
Frequency and Period Measurements
36
Quick Start
37
Basic Multimeter Operations
38
Preparing the Multimeter for Use
38
Using the Front Panel
39
Front-Panel Keys
39
Front-Panel Display Shortcuts
40
Making Basic Measurements
41
To Measure DC Voltage
42
To Measure AC Voltage
42
To Measure DC Current
43
To Measure AC Current
43
To Make a 2-Wire Resistance Measurement
44
To Make a 4-Wire Resistance Measurement
44
To Measure Frequency
45
To Measure Period
45
To Measure Capacitance
46
To Make a 2-Wire Temperature Measurement
47
To Make a 4-Wire Temperature Measurement
47
To Test Continuity
48
To Check Diodes
48
Other Basics of Operation
49
If the Multimeter Does Not Turn on
49
To Replace the Power-Line Fuse (34410A/11A)
50
To Adjust the Carrying Handle (34410A/11A)
51
To Rack Mount the 34410A/11A Multimeter
51
To Rack Mount the L4411A Multimeter
52
Calibration Operation (34410A/11A)
53
To Read the Calibration Count
53
To Read the Calibration Message
54
To Store a Calibration Message
54
To Secure for Calibration
55
To Unsecure for Calibration
56
To Re-Secure
56
Calibration Procedures
57
Agilent Technologies Calibration Services
58
Calibration Interval
58
Adjustment Is Recommended
58
Time Required for Calibration
59
Automating Calibration Procedures
59
Recommended Test Equipment
60
Performance Verification Tests
60
Self-Test
61
Quick Performance Check
61
Performance Verification Tests
62
Input Connections
62
Test Considerations
63
Verification Tests
64
Zero Offset Verification
64
Gain Verification
66
Optional AC Voltage Performance Verification Tests
72
Optional AC Current Performance Verification Tests
73
Optional Capacitance Performance Verification Tests
74
Calibration Security
75
To Unsecure the Instrument Without the Security Code
75
Calibration Message
77
Calibration Count
77
Calibration Process
78
Using the Front Panel for Adjustments (34410A/11A Only)
78
Selecting the Adjustment Mode
78
Entering Adjustment Values
78
Storing the Calibration Constants
78
Using the Remote Interface for Adjustments
79
Selecting the Adjustment Mode
79
Entering Adjustment Values
79
Storing the Calibration Constants
79
Aborting a Calibration in Progress
79
Adjustments
80
ADC and Zero Adjustment
80
Gain Adjustments
82
Flatness Adjustments
93
Finishing Adjustments
102
Disassembly and Repair
103
Operating Checklist
104
Types of Service Available
105
Extended Service Contracts
105
Obtaining Repair Service (Worldwide)
105
Repackaging for Shipment
106
Cleaning
106
To Replace the 34410A/11A Power Line Fuse
106
To Replace the Current Input Fuse
107
Self Test Procedures
107
Power-On Self-Test
107
34410A/11A Complete Self-Test
107
L4411A Complete Self-Test
107
Self Test Error Numbers
108
Calibration Errors
109
34410A/11A Display and Keypad Tests
110
Electrostatic Discharge (ESD) Precautions
110
34410A/11A Mechanical Disassembly
111
General Disassembly
111
Front Panel Removal
113
Front Panel Disassembly
116
L4411A Mechanical Disassembly
117
General Disassembly
117
Replaceable Parts
122
To Order Replaceable Parts
122
Parts List 34410A/11A
123
Parts List L4411A
124
Backdating
125
Advertisement
Agilent Technologies 34410A Datasheet (7 pages)
Brand:
Agilent Technologies
| Category:
Multimeter
| Size: 0.18 MB
Advertisement
Related Products
Agilent Technologies 34401A
Agilent Technologies 34420A
Agilent Technologies 34405A
Agilent Technologies 34450A 5 Digit Multimeter
Agilent Technologies 34450A
Agilent Technologies 34411A
Agilent Technologies 3458A
Agilent Technologies 3457A
Agilent Technologies Truevolt 34460A
Agilent Technologies Truevolt 34461A
Agilent Technologies Categories
Measuring Instruments
Laboratory Equipment
Test Equipment
Water Pump
Power Supply
More Agilent Technologies Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL