Media cage bezel
Figure 209. Retention bracket installation
12. Install the media cage (see "Replacing the media cage" on page 178).
13. Replace the top cover (see "Replacing the top cover" on page 147).
14. Slide the server into the rack.
15. Reconnect the power cords and any cables that you removed.
16. Turn on the peripheral devices and the server.

Removing the operator information panel assembly

Use this information to remove the operator information panel assembly.
About this task
To remove the operator information panel, complete the following steps.
Procedure
1. Read the safety information that begins on "Safety" on page vii and
2. Turn off the server and peripheral devices and disconnect the power cords and
3. Remove the top cover (see "Removing the top cover" on page 146).
4. Disconnect the cable from the back of the operator information panel assembly.
5. ▌1▐Pull up the release tab slightly and ▌2▐slide the operator information panel
254
System x3650 M5 Type 5462: Installation and Service Guide
"Installation guidelines" on page 283.
all external cables, if necessary.
assembly out of the server.