IBM System x3650 M5 Installation And Service Manual page 718

Type 5462
Table of Contents

Advertisement

816f0113-0301ffff • 816f0113-0302ffff
816f0113-0301ffff
System [ComputerSystemElementName] has recovered from a bus timeout. (CPU 1 PECI)
Explanation: This message is for the use case when an implemenation has detected that a system has recovered
from a Bus Timeout.
May also be shown as 816f01130301ffff or 0x816f01130301ffff
Severity: Info
Alert Category: Critical - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0225
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
(Trained technician only) Replace microprocessor n (see Removing a microprocessor and heat sink and Replacing
a microprocessor and heat sink).
2.
If the problem persists and there is no other CPU with the same error indication, replace the system board.
3.
(Trained technician only) Replace the system board (see Removing the system board and Installing the system
board). (n = microprocessor number)
816f0113-0302ffff
System [ComputerSystemElementName] has recovered from a bus timeout. (CPU 2 PECI)
Explanation: This message is for the use case when an implemenation has detected that a system has recovered
from a Bus Timeout.
May also be shown as 816f01130302ffff or 0x816f01130302ffff
Severity: Info
Alert Category: Critical - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0225
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
(Trained technician only) Replace microprocessor n (see Removing a microprocessor and heat sink and Replacing
a microprocessor and heat sink).
2.
If the problem persists and there is no other CPU with the same error indication, replace the system board.
3.
(Trained technician only) Replace the system board (see Removing the system board and Installing the system
board). (n = microprocessor number)
702
System x3650 M5 Type 5462: Installation and Service Guide