806f011b-0701ffff • 806f011b-0c01ffff
806f011b-0701ffff
The connector [PhysicalConnectorElementName] has encountered a configuration error. (Front
USB)
Explanation: This message is for the use case when an implementation has detected an Interconnect Configuration
Error.
May also be shown as 806f011b0701ffff or 0x806f011b0701ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0266
SNMP Trap ID: 50
Automatically notify Support: Yes
User response: If the specified sensor is front USB connector, reset the front USB cable on the system board. If the
specified sensor is front video connector, reset the front video cable in the system board. If the specified sensor is
PwrPaddle cable, complete the following steps until problem is solved:
1.
Reseat the power paddle cable on the system board.
2.
Replace the power paddle cable.
3.
(Trained technician only) Replace the supercap n. (n = supercap number)
4.
(Trained technician only) Replace the system board.
Front Video :
806f011b-0c01ffff
The connector [PhysicalConnectorElementName] has encountered a configuration error. (FP
LCD Cable)
Explanation: This message is for the use case when an implementation has detected an Interconnect Configuration
Error.
May also be shown as 806f011b0c01ffff or 0x806f011b0c01ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0266
SNMP Trap ID: 50
Automatically notify Support: Yes
User response:
1.
Check system event log is showing LCD cable sensor has deasserted.
2.
Reseat LCD cable on the system board.
3.
Reset LCD cable on LCD panel.
4.
Replace LCD cable.