Removing The Operator Information Panel Assembly - IBM x3550 Problem Determination And Service Manual

Type 7978; type 1913
Table of Contents

Advertisement

5. Use the thermal-grease syringe to place nine uniformly spaced dots of 0.02 mL
6. Continue with step 5 on page 89 of the "Installing a microprocessor" on page 87

Removing the operator information panel assembly

To remove the operator information panel, complete the following steps.
90
IBM System x3550 Type 7978 and 1913: Problem Determination and Service Guide
Microprocessor
each on the top of the microprocessor.
Note: 0.01mL is one tick mark on the syringe. If the grease is properly applied,
approximately half (0.22 mL) of the grease will remain in the syringe.
procedure.
1. Read the safety information that begins on page vii and "Installation guidelines"
on page 39.
2. Turn off the server and peripheral devices and disconnect all power cords;
then, remove the cover (see "Removing the cover" on page 42).
3. Open the fan door.
4. Remove the CD-RW/DVD drive (see "Removing the CD-RW/DVD drive" on
page 51).
0.02 mL of thermal
grease

Hide quick links:

Advertisement

Table of Contents
loading