IBM System x3650 M5 Installation And Service Manual page 399

Type 5462
Table of Contents

Advertisement

80010901-1403ffff
Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted.
(DIMM AB VR Temp)
Explanation: This message is for the use case when an implementation has detected an Upper Critical sensor going
high has asserted.
May also be shown as 800109011403ffff or 0x800109011403ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0494
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Reduce the ambient temperature.
2.
Ensure the air baffle is installed correctly.
3.
Check the server airflow. Make sure that nothing is blocking the air from coming into or preventing the air from
exiting the server.
80010901-1404ffff
Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted.
(DIMM CD VR Temp)
Explanation: This message is for the use case when an implementation has detected an Upper Critical sensor going
high has asserted.
May also be shown as 800109011404ffff or 0x800109011404ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0494
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Reduce the ambient temperature.
2.
Ensure the air baffle is installed correctly.
3.
Check the server airflow. Make sure that nothing is blocking the air from coming into or preventing the air from
exiting the server.
80010901-1403ffff • 80010901-1404ffff
Appendix A. Integrated management module II (IMM2) error messages