physical partition.
XSCF>   deleteboard -c unassign 00-0 01-0 02-0 03-0
PSB#00-0   will   be   unassigned   from   PPAR   immediately.   Continue?[y|n]   : y
PSB#01-0   will   be   unassigned   from   PPAR   immediately.   Continue?[y|n]   : y
PSB#02-0   will   be   unassigned   from   PPAR   immediately.   Continue?[y|n]   : y
PSB#03-0   will   be   unassigned   from   PPAR   immediately.   Continue?[y|n]   : y
5.
Execute the showresult command, and confirm the end status of the
previously executed deleteboard command.
In the following example, 0 is returned as the end status, so the execution of the
deleteboard command has completed correctly.
XSCF>   showresult
0
6.
Execute the showboards command to check the system board (PSB) status.
In the following example, system boards 00-0, 01-0, 02-0, and 03-0 are in the
system board pool.
XSCF>   showboards -a
PSB     PPAR-ID(LSB)   Assignment     Pwr     Conn   Conf   Test         Fault
----   ------------   -----------   ----   ----   ----   -------   --------
00-0   SP                       Available       n         n         n         Passed     Normal
01-0   SP                       Available       n         n         n         Passed     Normal
02-0   SP                       Available       n         n         n         Passed     Normal
03-0   SP                       Available       n         n         n         Passed     Normal
7.
Execute the initbb command from the master XSCF to release the target
SPARC M10-4S from the system and initialize it.
In bb_id, specify the ID (BB-ID) identifying the chassis.
XSCF>   initbb -b bb_id
The following example releases BB#03 from the system and initializes it.
XSCF>   initbb -b 3
You   are   about   to   initialize   BB/XB-Box.
NOTE   the   following.
1.   BB/XB-Box   is   excluded   from   the   system   and   halted.
2.   PPAR-ID   of   the   same   value   as   BB-ID   becomes   invalid.
Continue?   [y|n]   : y
Note - After the execution of the initbb command, the target chassis is released from the
system and enters the stopped state. Do not disconnect the power cords or various cables
until the XSCF STANDBY LED on the panel and the rear READY LED of the target chassis
are off.