Code128 and UCC/EAN 128 Options

Code 128 and UCC/EAN 128 Minimum Length

Follow these steps to set Code 128 and UCC/EAN 128 Minimum Label Length:
1. Identify the minimum length setting you want to make. The
selectable range is 01 to 50
2. Scan the SET label.
3. Scan the SET C128 MINIMUM LABEL LENGTH bar code.
Setting Lengths
If you are setting a length less than ten, you must scan a zero first and
then the length digit ( 04, 06, 08).
4. Set the minimum label length by scanning the correct digits
from below and the next page.
5. Scan the END label.
SET
--------------------------------------
S
C128/UCC/EAN 128 M
ET
0 ------------------------------
1 ------------------------------
2 ------------------------------
1
The scanner will decode up to 50 characters, but the actual length read will vary depending upon
interface type, the physical size of the bar code, print quality and whether the bar code data consists
of Code 128 code set A, set B, or set C characters. (The C128 character set C allows for more
densely packed data, thus if the bar code includes all or mostly C128 set C characters, more
characters can be decoded.)
92
1
characters.
L
L
INIMUM
ABEL
ENGTH