Follow these steps to set MSI/Plessey Minimum Label Length:
1. Identify the minimum length setting you want to make. The
selectable range is 01 to 50
2. Scan the SET label.
3.
Scan the VARIABLE LENGTH bar code from the MSI/Plessey
Length Control selection earlier in this section.
4. Scan the SET MSI/Plessey MINIMUM LABEL LENGTH
bar code.
Setting Lengths
If you are setting a length less than ten, you must scan a zero first and
then the length digit (04, 06, 08).
5. Set the minimum label length by scanning the correct digits
from below and the next page.
6. Scan the END label.
SET
--------------------------------------
S
ET
0 ------------------------------
1 ------------------------------
2 ------------------------------
1
For this symbology, the scanner will decode up to 50 characters, but the actual length read
will vary depending upon interface type, and bar code physical size and quality. 