The scanner will not transmit a label ID character if its hex value is set to
zero. If you have determined that you need a Label I.D. that contains only a
single character, follow this modified procedure:
1.
Scan the SET bar code.
2.
Scan your selection from the previous two pages for the symbol-
ogy identifier you plan to change.
For example, scan the EAN-8 bar code to select that symbology.
3.
Turn to the keypad (Appendix C of this manual) and scan the
two-digit hex code that represents your desired character (refer
to the ASCII chart on the inside back cover of this manual for
this conversion).
As an example, assume that you want to change the Label I.D. for
EAN-8 from the default setting "FF" to the single character "8". In
this example, note that the chart shows that the ASCII character
'8' is equivalent to 38
scanned.
If you make a mistake, or lose your place while setting
this option, scan the END bar code to exit Program-
ming Mode. The scanner will sound a two-beep error
tone to indicate that programming was incomplete,
and the setting will remain as it was before entering
Programming Mode.
4.
Scan the digit '0' two times to disable transmission of a second
character.
5.
Scan the END bar code.
Disabling Label I.D. for a Specific Symbology
This procedure is the same as setting a single character symbology identifier,
except you should scan four zeros before scanning the END bar code.
R44-1840
How to Set Single Character Label I.D.
therefore the digits 3, then 8 should be
hex,
NOTE