PSC PowerScan Programming Manual page 7

Handheld laser scanner
Hide thumbs Also See for PowerScan:
Table of Contents

Advertisement

To determine if your desired new interface is available on your scanner, check
the following section titled "Software". The section lists host interface types
supported by each interface board available at the time of this writing. If you
are still unsure of your scanner's available interface connectivity, consult your
PSC dealer
The scanner will need to be sent to a Level I Service repair depot if the
interface board must be swapped; however, if necessary, you can change your
scanner's interface cable by following these instructions. (Refer to Figure 1.):
1.
Loosen the screw at the bottom of the handle. This screw is
captive and does not come all the way out.
2.
Swing the forked cable retainer clear of the square hole in the end
cap and rotate away from the cable.
3.
Holding the scanner handle and end cap together in one hand, pull
the connector out of the handle end cap to free the interface cable.
4.
Connect the new interface cable at the scanner and rotate the
forked cable retainer to secure it. Tighten the screw to between 6 and
10 in-lbs.
Figure 1. Removing/Replacing the Interface Cable and Board