LOW PRESSURE FUEL PUMP
REMOVAL / INSTALLATION
REMOVAL
1. Disconnect inlet hose
sure fuel pump.
2. Remove two bolts
3. Remove fuel pump
INSTALLATION
Installation is reverse order of removal with special attention to
the following steps.
• Before installing fuel pump, rotate the crankshaft to
bring No.1 (top cylinder) piston to Top Dead Center
on compression stroke.
• Discard O-rings after removal. always use new O-ring
to ensure proper sealing.
Low pressure fuel pump bolt :
and outlet hose
from low pres-
.
and O-ring
.
10 N . m (1.0 kg-m, 7.2 lb.-ft.)
FUEL SYSTEM
5-14