4-17 ELECTRICAL
MONITOR-TACHOMETER
INSPECTION
MONITOR LAMP CHECK
(1) Connect the test cord as shown.
09930-89240 : 4-pin test cord
NOTE:
This check can be performed without the test cord (P/no. 09930-
89240). If it is not available, directly connect battery to terminal
of meter.
(2) Apply 12V power to meter. Connect Gray wire to positive (+)
terminal, and Black wire to negative (–) terminal of battery.
(3) Check if lamp lights when connecting battery to test cord
terminal as shown.
Monitor lamp check:
battery connection
Battery terminal
Test cord
Negative (–)
Negative (–)
Negative (–)
Positive (+)
If out of specification, replace monitor-tachometer.
Terminal for
Lighting lamp
Meter
Bl
G/W
W
G/Y
Y
Bl/B
R
P
Lamp
Lamp
Lamp
Lamp
"CHECK ENGINE"
TEMP "
"
OIL "
"
REV "LIMIT"
B
Gr
12V
Battery
G/W
P
G/Y
Bl/B
Bl
W
Y
12V
Battery
12V
R
Battery