IBM 5170 Technical Reference page 64

Hide thumbs Also See for 5170:
Table of Contents

Advertisement

04
The
I
keyboard data
I
line is stuck high.
AC
Diagnostic Dump-Sends 16 bytes of the controller's
RAM, the current state of the input port, the current
state of the output port, and the controller's program
status word to the system. All items are sent in scan-code
format.
AD
Disable Keyboard Feature-This command sets bit 4 of
the controller's command byte. This disables the
keyboard interface by driving the clock line low. Data
will not be sent or received.
AE
Enable Keyboard Interface-This command clears bit 4
of the command byte, which releases the keyboard
interface.
CO
Read Input Port-This commands the controller to read
its input port and place the data in its output buffer. This
command should be used only if the output buffer is
empty.
DO
Read Output Port-This command causes the controller
to read its output port and place the data in its output
buffer. This command should be issued only if the output
buffer is empty.
Dl
Write Output Port-The next byte of data written to I/O
address hex 60 is placed in the controller's output port.
Note: Bit 0 of the controller's output port is
connected to System Reset. This bit should not be
written low.
EO
Read Test Inputs-This command causes the controller
to read its TO and Tl inputs. This data is placed in the
output buffer. Data bit 0 represents TO, and data bit 1
represents T 1.
FO-FF
Pulse Output Port-Bits 0 through 3 of the controller's
output port may be pulsed low for approximately 6
microseconds. Bits 0 through 3 of this command indicate
1"""""'\
1"""""'\
~
1-42 System Board

Hide quick links:

Advertisement

Table of Contents
loading