5. Adjusting the CCD PC Board
a. Enter Service Mode No. 5-1 (see Section 5.5.1 [CCD Test]).
b. Monitoring the Oscilloscope, carefully adjust the position of the CCD Board until the output is obtained as shown
below. Make sure that the ADF Door is closed.
c. Carefully tighten both mounting screws on the CCD PC Board.
CCD out
6. Disconnect the Oscilloscope and reassemble the machine.
7. Run a test in Copy Mode to ensure the until is working properly.
91
Approx.
300mv