Lexmark 363dn Service Manual page 111

Hide thumbs Also See for 363dn:
Table of Contents

Advertisement

Sensor2 test
This test verifies the functionality of scan sensor 2. To test this sensor, perform the following steps:
1.
In the sensor test menu, press
2.
). Starting Test displays. Sensor 2: Closed displays.
Press Select (
3.
Lift the ADF top cover, and close the ADF cover sensor (A) by pressing down on the ADF sensor actuator
with a small flatblade screwdriver.
4.
Move the Sensor 2 actuator by inserting a small screwdriver into the hole (B) and gently toggling the
actuator. Sensor 2: Open should display if the sensor is working properly.
5.
Press Back (
) to exit the test and return to the Scanner sensor tests.
or
to scroll to the Sensor 2 test.
A
B
7013-XXX
3-21
Diagnostic aids