Preventive Maintenance; Safety Inspection Guide; Lubrication Specifications; Maintenance Kits - Lexmark 363dn Service Manual

Hide thumbs Also See for 363dn:
Table of Contents

Advertisement

6. Preventive maintenance

This chapter describes procedures for printer preventive maintenance. Follow these recommendations to help
prevent problems and maintain optimum performance.

Safety inspection guide

The purpose of this inspection guide is to aid you in identifying unsafe conditions.
If any unsafe conditions exist, then find out how serious the hazard could be and if you can continue before you
correct the hazard.
Check the following items:
Damaged, missing, or altered parts, especially in the area of the On/Off switch and the power supply
Damaged, missing, or altered covers, especially in the area of the top cover and the power supply cover
Possible safety exposure from any non-Lexmark attachments

Lubrication specifications

FRUs are typically lubricated as needed from the factory. If not, then lubricate only when parts are replaced or as
needed, not on a scheduled basis. Use of lubricants other than those specified can cause premature failure.
Some unauthorized lubricants may chemically attack parts. Use P/N 99A0394 (Nyogel 744) to lubricate
appropriate areas. Lubricate gears that were lubricated in the original part.

Maintenance kits

Maintenance kits include:
Fuser (P/N 40X5344, 40X5345, or 40X5346)
Exit guide (P/N 40X5372)
Tray 1 ACM feed tires (P/N 40X5451)
Transfer roll (P/N 40X5364)
ADF (P/N 40X5807)
Maintenance kits
Description
Low voltage (110 V) maintenance kit
High voltage (220 V) maintenance kit
100 V maintenance kit
Part number
40X5400
40X5401
40X5402
7013-XXX
Preventive maintenance
6-1

Advertisement

Table of Contents
loading

Table of Contents