EM SERVER POWER SUPPLY REPLACEMENT
Power UP Server
Figure 16-1 EM Server Fan Location
EM SERVER POWER
SUPPLY REPLACEMENT
16-12
1. Connect the AC Power cords.
2. Set the rear panel switches to ON.
3. Wait one minute then, press the front panel Power Switch.
You do not need to shut down the system to replace an EM server power
supply module. The redundant power supply feature will keep the system
up and running while you replace the failed hot-swap module. Replace
the power supply module with the same model, which can be ordered
from Toshiba.
1. The failed power supply led will change from green to amber. First
unplug the power cord from the failed power supply module.
2. To remove the failed power module, push the release tab (on the back
of the power supply) to the side and then pull the module straight out.
Refer to
Figure
16-2.
3. The power supply wiring was designed to detach automatically when
the module is pulled from the chassis.
4. Replace the failed power module with another PWS-651-1R power
supply module.
5. Simply push the new power supply module into the power bay until
you hear a click.
6. Finish by plugging the AC power cord back into the module.
Power UP Server
Installation Manual
August, 2011