VISTA-50P/VISTA-50PUL Installation and Setup Guide

Zone Number Designations

The VISTA-50P/VISTA-50PUL supports up to 86 zones
of hardwire, polling loop and/or wireless protection,
distributed among up to 8 partitions. The following
table lists the zone numbers and the types of sensors
that can be used with each, and some alternate
functions of the zones.
Zone
Function
1
2-wire Smoke Detectors (if used)
5
Audio Alarm Verification (if used)
7
Keyswitch (if used)
8
Latching-Type Glassbreak Detectors (if used)
1-9
Traditional Hardwired Zones
9
Selectable for fast response devices (if used)
1-86
5800 Series Wireless Devices
10-86
Polling Loop Devices
✳ + 1 Panic
95
96
# + 3 Panic
✳ + # Panic
99
Zone Defaults
Zone #
Zone Type
01
09
02
03
03
03
04
04
05
03
06
03
07
03
08
03
09
03
10–86
00
87
00
*
Zone 992 is the Duress zone. Programming of the zone
response type is not applicable. This zone requires only the
report code programming.
Communication Defaults
*45
PRIMARY FORMAT
*46
LOW SPEED FORMAT (Prim) [0]
*47
SECONDARY FORMAT
*48
LOW SPEED FORMAT (Sec.) [0]
*49
CHECKSUM VERIFICATION [0]
No checksum
*50
SESCOA/RADIONICS SEL.
4-4
Zone #
Zone Type
88
00
89
00
90
00
91
00
92*
N/A
95
00
96
00
97
05
98
00
99
06
[1]
ADEMCO Contact ID
ADEMCO Low Speed
[1]
ADEMCO Contact ID
ADEMCO Low Speed
[0]
Primary
Secondary
[0]
Radionics
WWW.DIYALARMFORUM.COM
Zone Index
The zones are designated as follows:
ZONE #
ZONE
RANGE
FUNCTION
01 – 86
Protection
zones
87, 88, 89,
System
90, 91, 97
Supervisory
& 98
Zones
92, 95 – 99
Duress and
Keypad Panics
Supervisory zones should be given a response type of 05
(Trouble by Day, Alarm by Night).
*51
DUAL REPORTING
*52
STANDARD/EXPANDED REPORT FOR PRIMARY
[0]
[0]
[0]
Alarm Rstr
Bypass
*53
STANDARD/EXPANDED REPORT FOR SECONDARY
[0]
[0]
[0]
Alarm Rstr
Bypass
ACTUAL ZONE
As indicated
87:
VIP Module Supervision
nd
88:
2
Wireless Receiver –
not receiving signals
nd
89:
2
Wireless Receiver –
not talking to control
st
90:
1
Wireless Receiver –
not receiving signals
st
91:
1
Wireless Receiver –
not talking to control
97:
Polling Loop (short
circuit)
98:
Bell Supervision
92:
Duress
1 + ✳ panic (A key)
95:
96:
3 + # panic (C key)
✳ + # panic (B key)
99:
[0]
no
[0]
[0]
[0]
standard
Trbl
Opn/Cls Low Bat
[0]
[0]
[0]
standard
Trbl
Opn/Cls Low Bat