Other Methods of Arming/Disarming
Common Lobby logic remains active when arming or
disarming a partition that affects and/or arms the
common lobby in one of the following manners:
Quick-Arm
Keyswitch
Wireless Button
Wireless Keypad
Arming/Disarming Remotely
The lobby does not automatically arm or disarm if a
user arms or disarms remotely, via Compass
downloading software. The lobby must be armed
separately, after arming all affecting partitions first.

Master Keypad Setup and Operation

Although this system has eight actual partitions, it
provides an extra partition strictly for the purpose of
assigning keypads as Master keypads for the system.
Assigning any keypad to Partition 9 in Device
Programming in the #93 Menu Mode makes that
keypad a Master keypad. A Master keypad reflects the
status of the entire system (Partitions 1-8) on its
display at one time. This is useful because it eliminates
the need for a building security officer to have to log on
to various partitions from one partition's keypad to find
out where an alarm has occurred.
The following is a typical display:
S Y S T E M 1 2 3 4 5 6 7 8
S T A T U S R R N N A 7 B
Possible status indications include:
A = Armed Away
S = Armed Stay
I = Armed Instant
R = Ready
B = Bypassed/Ready
= Alarm/Trouble
To obtain more information regarding a particular
partition, enter [✴] + Partition No. (e.g., [✴] + [4]). This
allows viewing only of that partition. In order to affect
that partition, the user must use a code that has access
to that partition. Also, in order for a user of any
partition to log on to Partition 9 to view the status of all
partitions, that user must have access to all partitions.
Otherwise, access is denied.
The following is displayed for a fault condition on Zone
2 (Loading Dock Window) on Partition 1 (Warehouse)
when a user logs on from a keypad on Partition 9:
WHSE DISARMED
HIT 7 FOR FAULTS
M = Armed Maximum
N = Not Ready
WWW.DIYALARMFORUM.COM
Section 3 - Installing the Control
Auto-Arming/Disarming
If scheduling is used to automatically arm and/or
disarm partitions, the common lobby partition does not
automatically follow another partition that is
programmed to arm or disarm the lobby.
The lobby must be included as a partition to be
armed/disarmed and must be scheduled as the last
partition armed.
If you are using auto-arming, make sure that
the Auto-Arm Delay and Auto-Arm Warning
periods, for the lobby partition, (fields 2*05 and
2*06) combined are longer than that of any
other partition that affects the lobby. This
causes the lobby to arm last.
Pressing [✴] causes the following display to appear at
Partition 1's keypad(s):
FAULT 002 LOADING
DOCK WINDOW
Additional zone faults are displayed one at a time. To
display a new partition's status, press [✴] + Partition
No.
The Armed LED on a Master keypad is lit only if all
partitions have been armed successfully. The Ready
LED is lit only if all partitions are "ready to arm."
Neither LED is lit if only some partitions are armed
and/or only some partitions are ready.
Press [✴] + [0] or [✴] + [9] to return to the master
partition. Otherwise, if no keys are pressed for 2
minutes, the system automatically returns to the
master partition
The sounder on a Master keypad reflects the sound of
the most critical condition on all of the partitions. The
priority of the sounds, from most to least critical, is as
follows:
1.
Pulsing fire alarm sounds
2.
Steady burglar alarm sounds
3.
Trouble sounds (rapid beeping)
Silence the sounder by pressing any key on the Master
keypad or a keypad on the partition where the condition
exists.
A Master keypad uses the same panics as
Partition 1. Master keypad panics are sent to
Partition 1, and will activate on Partition 1.
Therefore, panics must be programmed for
Partition 1.
2-3