Following is a list of commands used while in the Menu Mode:
#
9
3
M
e
n
u
M
o
d
e
P
r
o
#
9
3
M
e
n
u
M
o
d
e
P
r
o
#93
Enters Menu Mode.
Serves as [ENTER] key. Press to have keypad accept entry and scroll forward.
[∗]
[#]
Backs up to previous screen.
0
Press to answer NO.
1
Press to answer YES.
00, or 000+[∗]
Quits Menu Mode and goes back to Data Field Programming Mode, if entered at first prompt of each main menu
option.
Z
o
n
e
N
u
m
b
e
r
D
e
s
Z
o
n
e
N
u
m
b
e
r
D
e
s
The VISTA-128BPT supports up to 128 zones, the
VISTA-250BPT supports up to 250 zones, of hardwire,
polling loop and/or wireless protection, distributed
among up to eight partitions. The following table lists
the zone numbers and the types of sensors that can be
used with each, and some alternate functions of the
zones.
Zone
Function
001
2-wire Smoke Detectors (if used)
005
Audio Alarm Verification (if used)
007
Keyswitch (if used)
001-009
Traditional Hardwired Zones
009
For unsupervised, N.C. use only.
001-250
5800 Series Wireless Devices
010-250
Polling Loop Devices
∗ + 1 Panic
995
996
# + 3 Panic
∗ + # Panic
999
Z
o
n
e
D
e
f
a
u
l
t
s
Z
o
n
e
D
e
f
a
u
l
t
s
Zone #
Zone Type
001
09
002
03
003
03
004**
04
005
03
006
03
007
03
008
03
009
03
010–250
00
NOTES:
* Zone 992 is the Duress zone. Programming of the zone
response type is not applicable. This zone requires only
the report code programming.
** Zone 004 is also defaulted with Auto-STAY enabled.
g
r
a
m
m
i
n
g
C
o
m
m
a
n
d
g
r
a
m
m
i
n
g
C
o
m
m
a
n
d
i
g
n
a
t
i
o
n
s
i
g
n
a
t
i
o
n
s
Zone #
Zone Type
601-632
00
800-830
00
970
00
988
00
990
00
992*
N/A
995
00
996
00
997
05
999
06
s
s
Z
o
n
e
I
n
d
e
Z
o
n
e
I
n
d
e
The zones are designated as follows:
ZONE #
RANGE
001 – 250
601 – 632
800 – 830
970, 988,
990, & 997
992, 995 –
999
Program supervisory zones with response type of 05.
C
o
m
m
u
n
i
C
o
m
m
u
n
i
∗45
PRIMARY FORMAT
∗47
SECONDARY FORMAT
∗51
DUAL REPORTING
9
SECTION 2: PROGRAMMING
x
x
ZONE
ACTUAL ZONE
FUNCTION
As indicated
Protection
zones
6 + 2-digit Relay Number; e.g.,
Relay
Relay Number 03 is zone 603.
Supervisory
Zones
ECP Device
8 + 2-digit Device Address; e.g.,
Supervisory
Device Address 01 is zone 801.
Zones
System
970: Bell Supervision
Supervisory
988: 2nd Wireless Receiver –
Zones
not receiving signals
990: 1st Wireless Receiver – not
receiving signals
997: Polling Loop (short circuit)
Duress and
992: Duress
Keypad
995: 1 + ∗ panic (A key)
Panics
996: 3 + # panic (C key)
999: ∗ + # panic (B key)
c
a
t
i
o
n
D
e
f
a
u
l
t
s
c
a
t
i
o
n
D
e
f
a
u
l
t
s
[1]
ADEMCO Contact ID
[1]
ADEMCO Contact ID
[0]
no

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vista-250bptVista-128bptsia

Table of Contents