6.
Use the Battery Selection Table to select the
appropriate battery for the installation.
Table 6: Battery Selection Table
Capacity
Recommended Battery
4AH
Yuasa NP4-12
7AH
Yuasa NP7-12
12AH
Yuasa NP12-12
14AH
Yuasa NP7-12
17.2AH
Yuasa NPG18-12
Comment
Fits in large
mercantile
cabinet only.
Connect two
in parallel.
Fits in large
mercantile
cabinet only.
WWW.DIYALARMFORUM.COM
Section 3 - Installing the Control
7.
Connect the battery, referring to Figure 3-28.
The standby battery is automatically tested for
10 minutes every 4 hours, beginning 4 hours
after exiting Programming mode. In addition,
entry into the Test mode initiates a battery test.