VISTA-50P/VISTA-50PUL Installation and Setup Guide
FIELD
TITLE and DATA ENTRIES
Daylight Saving Time Start/End
2*02
Weekend
0 = disable
1 = enable
U L
Fields 2*05 – 2*08 must be set to 0 for UL installations.
Auto-Arm Delay (partition-
2*05
specific)
00 = no delay.
01-14 times 4 minutes (04-56) delay.
15 = no auto arming.
Auto-Arm Warning Period
2*06
(partition-specific)
01-15 times 1-minute warning.
00 = no warning period.
Auto-Disarm Delay (partition-
2*07
specific)
00 = no delay.
01-14 times 4 minutes (04-56) delay.
15 = no auto disarming.
Force Arm Enable for Auto-Arm
2*08
(partition-specific)
0 = disable
1 = enable
Open/Close Reports by
2*09
Exception (partition-specific)
0 = disable
1 = enable
Allow Disarming Only During
2*10
Arm/Disarm Windows (partition-
specific)
0 = disable
1 = enable
Allow Disarm Outside Window if
2*11
Alarm Occurs
0 = disable
1 = enable
Scheduling Report Codes (First
2*13
Digit
Enter 00-15.
5-14
EXPLANATION
Enter the start and end weekends for daylight saving time as follows:
1=first; 2=second; 3=third; 4=fourth; 5=last; 6=next to last; 7=third from
last. Standard setting for U.S. is 1,5.
This is the time between the end of the arming window and the start of
auto-arm warning time (field 2*06).
This is the time that the user is warned by a keypad sounding and display
to exit the premises prior to auto arming of the system.
This is the time between the end of the disarming window and the start of
auto disarming of the system.
If enabled, the system automatically bypasses any faulted zones when it
attempts to auto-arm.
If disabled, the system will not auto-arm.
If enabled, Open/Close reports are sent only if the openings/closings
occur outside the arm and disarm windows.
NOTES:
Open reports are also suppressed during the closing window in order to
prevent false alarms if the user arms the system, then re-enters the
premises, for example to retrieve a forgotten item.
Openings and closings are still recorded in the event log.
This field must be set to 1 if No Opening and No Closing reports are to be
sent.
If enabled, disarming of the system is allowed only during the
arming/disarming windows, or if the system is in alarm (if 2*11 is set to
1).
NOTE: This applies only to Operator-level users. Installer, Master, and
Manager-level users can disarm the system at any time.
If enabled, allows the system to be disarmed outside the programmed
disarm (opening) window if an alarm has occurred. Otherwise disarming
is allowed only during the disarm window.
NOTE: Used only if field 2*10 is enabled.
This field has eight two-digit entries as follows: Early Opening, Early
Closing, Late Opening, Late Closing, No Opening (late to open), No
Closing (late to close), Auto-Arm Failure, and Access Schedule Changed.
Enter the report code 01-15 for each type of report. Enter 00 for no report.