Call Waiting Defeat; Wireless Keypad Tamper Detect; Chime On External Siren; Wireless Keypad Assignment - Honeywell VISTA-50P Installation And Setup Manual

Ademco vista series
Hide thumbs Also See for VISTA-50P:
Table of Contents

Advertisement

VISTA-50P/VISTA-50PUL Installation and Setup Guide
FIELD
TITLE and DATA ENTRIES
Non-Alarm Report Codes Report
1*41
Codes (Second Digit)
Enter 00-15.

Call Waiting Defeat

1*42
0 = disable
1 = enable
Permanent Keypad Display
1*43
Backlighting (partition-specific)
0 = disable
1 = enable

Wireless Keypad Tamper Detect

1*44
0 = disable
1 = enable
Exit Delay Sounding (partition-
1*45
specific)
0 = disable
1 = enable
Auxiliary Output Mode
1*46
0 = ground start output.
1 = open/close trigger.
2 = keypad sounds at an auxiliary sounder.
3 = AAV module.

Chime on External Siren

1*47
(partition-specific)
0 = disable
1 = enable

Wireless Keypad Assignment

1*48
0 = none
1-8 = partition number
Suppress Transmitter
1*49
Supervision Sound
0 = disable
1 = enable

Send Cancel If Alarm + Off

1*52
(partition-specific)
0 = disable
1 = enable

Disable Download Callback

1*53
0 = callback required
1 = no callback required
5-12
EXPLANATION
This field has seven two-digit entries as follows: Arm STAY, Time/Date
set or Event Log Reset, Event Log 50% or 90% Full, Event Log Overflow,
Exit Error (Zone), Exit Error (User) and Recent Close. Enter the report
code 01-15 for each type of report. Enter 00 for no report.
If enabled, the system defeats Call Waiting on the first outgoing call
attempt to both the primary and secondary numbers.
NOTES:
After the panel's initial call to report the alarm, the panel may attempt to
make an additional call, perhaps for a cancel or a zone restoral. If Call
Waiting is not defeated, an operator at the central station attempting to
contact the premises (to verify whether the alarm is valid) hears the
phone ringing indefinitely and must to dispatch on the call.
DO NOT enable this feature unless Call Waiting is being used.
If enabled, backlighting for the keypad display remains on at all times.
Otherwise the backlighting comes on when a key is pressed.
NOTE: When a key is pressed, display backlighting turns on for all
keypads in that partition.
If enabled, when more than 40 key depressions are received without a
valid sequence (arm, disarm, etc.), the control panel disables the wireless
keypad. The inhibit is removed once a valid key sequence is received from
a wired keypad.
If enabled, the system produces slow beeping from the keypads during
exit delay and reverts to rapid beeping during the last 10 seconds of the
exit delay.
NOTE: The duration of the beeping is the programmed value of field *10
regardless of which entry/exit zone is used to exit the premises.
Select the mode for output 1 on the J7 triggers.
NOTES:
Only one of the options may be active within the system.
Selection 1 is produced only when all partitions are armed.
Selection 2 applies only to the partition enabled in field *15.
If enabled, the system produces chime annunciation on the external
alarm sounder.
Select the partition in which RF keypad is used.
If enabled, no trouble soundings occur on the keypad for transmitter
check-in failures.
Must be 0 for UL.
If enabled, Cancel reports are sent when the system is disarmed after an
alarm, regardless of how much time has gone by.
If disabled, Cancel reports are sent within Bell Timeout period only.
NOTE: This option must be enabled so Cancel reports are always sent.
Select whether a callback from the control panel is required for
downloading.
Must be 0 for UL installations.