FIELD
TITLE and DATA ENTRIES
RF Transmitter Low Battery
1*28
Sound
0 = disarmed state only
1 = both armed and disarmed states
RF Transmitter Low Battery
1*29
Reporting
0 = disable
1 = enable
RF Receiver Supervision Check-
1*30
in Interval
Enter 02-15 times 2 hours (4-30 hours).
00 = disable receiver supervision.

RF Transmitter Check-in Interval

1*31
Enter 02-15 times 2 hours (4-30 hours).
00 = disable transmitter supervision.

TouchTone with Rotary Backup

1*33
0 = disable
1 = enable
Communicator Split Reporting
1*34
0 = Split Reporting disabled
1 = Alarm, Alarm Restore, and Cancel
reports to primary, all others to secondary
2 = Open/Close and Test reports to
secondary, all other reports to primary
Alarm Code for Zones 65–72
1*35
ID Digit for Zones 65–72
1*36
Alarm Code for Zones 73–80
1*37
ID Digit for Zones 73–80
1*38
Supervisory and Restore Codes
1*39
for Zones 65–80
Enter 00-15.
Non-Alarm Report Codes (First
1*40
Digit)
Enter 00-15.
EXPLANATION
Select when the RF transmitter low-battery condition should display and
audible beep annunciate on the keypad.
Must be 1 for UL installations.
If enabled, the system sends a Trouble message for RF transmitter low-
battery condition to the central station.
NOTE: The Trouble message will be sent for a transmitter supervision
failure, independent of this selection.
Must be 1 for UL.
Select the check-in monitoring interval for the RF receiver(s).
Failure of a receiver to receive any RF signal within the time entered
results in the activation of the response type programmed for zone 990 for
the first receiver and zone 988 for the second receiver and their related
communication reports.
Maximum is 2 (4 hr) for UL installations.
Select the check-in monitoring interval for the RF transmitters.
Failure of an individual transmitter to send a supervision signal within
the time entered will result in a trouble response and related
communication report.
Maximum is 2 (4 hr) for UL.
If enabled, the system reverts to rotary dialing if communicator is not
successful in dialing using TouchTone DTMF on first attempt.
Select the type of split reporting for system communication.
NOTE: See *51 for split/dual reporting combinations.
Skip this field. Use #93 Menu Mode, Zone Programming to program the
response types. Refer to the Programming Guide for details.
Skip this field. Use #93 Menu Mode, Zone Programming to program the
response types. Refer to the Programming Guide for details.
Skip this field. Use #93 Menu Mode, Zone Programming to program the
response types. Refer to the Programming Guide for details.
Skip this field. Use #93 Menu Mode, Zone Programming to program the
response types. Refer to the Programming Guide for details.
This field has five two-digit entries as follows: Alarm Restore, Trouble,
Trouble Restore, Bypass, and Bypass Restore. Enter the report code 01-15
for each type of report. Enter 00 for no report.
NOTE: Each report code is the same for zones 17-32. When using 4+2
format, the system uses the ID digit of the zone (fields *75 and *77).
This field has seven two-digit entries as follows: Arm STAY, Time/Date
set or Event Log Reset, Event Log 50% or 90% Full, Event Log Overflow,
Exit Error (Zone), Exit Error (User) and Recent Close. Enter the report
code 01-15 for each type of report. Enter 00 for no report.
WWW.DIYALARMFORUM.COM
Section 5 – Data Field Descriptions
5-11