Figure 3-20: 5881 Rf Receiver (Cover Removed); House Id Sniffer Mode - Honeywell VISTA-50P Installation And Setup Manual

Ademco vista series
Hide thumbs Also See for VISTA-50P:
Table of Contents

Advertisement

CIRCUIT
BOARD
MOUNTING
HOLES
Installing the 5800TM Module
Installation of this module is necessary only if you are
using a 5827BD or 5804BD Bi-directional device.
The address for the 5800TM must be enabled
in the control's Device Programming in the #93
Menu Mode as a keypad and then assigned to
a partition.
To install the 5800TM, perform the following steps:
Step
Action
1
Mount the unit using its accompanying
mounting bracket near the RF receiver.
The 5800TM must not be installed within
the control cabinet. It must be between
one and two feet from the receiver's
antennas.
2
Set the module for the appropriate address.
For Address Setting 28 cut the red jumper;
for Address 29 cut the white jumper; for
Address 30 cut both jumpers.
Make sure the address setting is not
being used by another device (keypad,
relay module, etc.).
3
Connect the module's wire harness to the
keypad terminals (6, 7, 8, and 9). Plug the
connector at the other end of the harness into
the module.
ANTENNAS
INSERT IN
RIGHT-HAND
TERMINALS
DIP SWITCH
INTERFERENCE
INDICATOR LED
DIP SWITCH #5 (PRESET ONLY ON 5881EH)
ON: SETS 5881EH FOR USE IN COMMERCIAL
FIRE APPLICATIONS (SEE THE RECEIVER'S
INSTRUCTIONS)*.
OFF: USE IN NON-COMMERCIAL FIRE
INSTALLATIONS.
* FOR COMMERCIAL FIRE APPLICATIONS
THE 5881EH PC BOARD MUST BE MOUNTED
IN A SEPARATE CABINET (SEE RECEIVER'S
INSTRUCTIONS FOR DETAILS).

Figure 3-20: 5881 RF Receiver (cover removed)

WWW.DIYALARMFORUM.COM
TO CONTROL'S REMOTE KEYPAD
CONNECTION POINTS.
USE MAX. of 220 ft. [67m of #22 (0.64mm)
WIRE or 550 ft. (168m) of #18 (1mm) WIRE
FOR EACH RUN. OBSERVE 20 ft. MAX.
FOR COMMERCIAL FIRE INSTALLATIONS.
(SEE RECEIVER'S INSTRUCTIONS.)
YELLOW
DIP SWITCH WHITE AREAS = SWITCH
RED
HANDLES. POSITION 2-4 DETERMINE
BLACK
RECEIVER'S ADDRESS. CONSULT
CONTROL'S INSTRUCTIONS FOR
GREEN
ADDRESS TO USE. DIP SWITCH BELOW
SHOWN SET FOR ADDRESS "0."
WIRING
OPENING
PLUG & SOCKET

House ID Sniffer Mode

This mode applies only if you are using a wireless
keypad (e.g., 5827) or bi-directional devices (e.g.,
5804BD). Use the House ID Sniffer mode to make sure
you do not choose a House ID that is in use in a nearby
system. The House ID must be programmed for the
receiver in Device Programming in the #93 Menu Mode.
To enter House ID Sniffer mode, enter your Installer
Code + [#] + [2].
The receiver now "sniffs" out any House IDs in the area
and displays them. Keep the receiver in this mode for
about 2 hours. Use a House ID that is not displayed.
Exit the Sniffer mode by entering your Installer Code
+ OFF.
As Sniffer mode effectively disables RF point
reception, Sniffer mode cannot be entered
while any partition is armed.
Section 3 - Installing the Control
RECEIVER ADDRESS SETTINGS
SWITCH
POSITION
(" - " MEANS OFF)
0
1
2
3
4
5
PRESENT ONLY ON 5881EH (SEE TEXT AT LEFT)
5
ON
ON
ON
4
ON
ON
ON
3
ON
ON
ON
2
1
FOR FUTURE USE
6
7
ON
ON
ON
3-15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vista-50pul

Table of Contents