Honeywell VISTA-50P Installation And Setup Manual page 55

Ademco vista series
Hide thumbs Also See for VISTA-50P:
Table of Contents

Advertisement

FIELD
TITLE and DATA ENTRIES
Alarm Code for Zones 49–56
*69
ID Digit for Zones 49–56
*70
Alarm Code for Zones 57–64
*71
ID Digit for Zones 57–64
*72
Supervisory and Restore Codes
*73
for Zones 49–64
Enter 00-15.
Alarm Code for Zones 81–88
*74
ID Digit for Zones 81–88
*75
Alarm Code for Zones 89–99
*76
ID Digit for Zones 89–99
*77
Supervisory and Restore Codes
*78
for Zones 81–99
Enter 00-15.
Zone Type Restores for Zone
*79
Types 1-8
0 = disable
1 = enable
Zone Type Restores for Zone
*80
Types 9, and 10
0 = disable
1 = enable
Non-Alarm Report Codes (First
*81
Digit)
Enter 00-15.
Non-Alarm Report Codes
*82
(Second Digit)
Enter 00-15.
EXPLANATION
Skip this field. Use #93 Menu Mode, Zone Programming to program the
response types. Refer to the Programming Guide for details.
Skip this field. Use #93 Menu Mode, Zone Programming to program the
response types. Refer to the Programming Guide for details.
Skip this field. Use #93 Menu Mode, Zone Programming to program the
response types. Refer to the Programming Guide for details.
Skip this field. Use #93 Menu Mode, Zone Programming to program the
response types. Refer to the Programming Guide for details.
This field has five two-digit entries as follows: Alarm Restore, Trouble,
Trouble Restore, Bypass, and Bypass Restore. Enter the report code 01-15
for each type of report. Enter 00 for no report.
NOTE: Each report code is the same for zones 49-64. When using 4+2
format, the system uses the ID digit of the zone (fields *70 and *72).
Skip this field. Use #93 Menu Mode, Zone Programming to program the
response types. Refer to the Programming Guide for details.
Skip this field. Use #93 Menu Mode, Zone Programming to program the
response types. Refer to the Programming Guide for details.
Skip this field. Use #93 Menu Mode, Zone Programming to program the
response types. Refer to the Programming Guide for details.
Skip this field. Use #93 Menu Mode, Zone Programming to program the
response types. Refer to the Programming Guide for details.
This field has five two-digit entries as follows: Alarm Restore, Trouble,
Trouble Restore, Bypass, and Bypass Restore. Enter the report code 01-15
for each type of report. Enter 00 for no report.
NOTE: Each report code is the same for zones 17-32. When using 4+2
format, the system uses the ID digit of the zone (fields *75 and *77).
This field has eight entries, one for each zone type. Select the zone types
that will send Restore reports.
This field has three entries, one for each zone type. Select the zone types
that will send Restore reports.
This field has ten two-digit entries as follows: Close, Open Low Battery,
Low Battery Restore, AC Loss, AC Restore, Test, Power-up, Cancel, and
Program Tamper. Enter the report code 01-15 for each type of report.
Enter 00 for no report.
This field has ten two-digit entries as follows: Close, Open, Low Battery,
Low Battery Restore, AC Loss, AC Restore, Test, Power-up, Cancel, and
Program Tamper. Enter the report code 01-15 for each type of report.
Enter 00 for no report.
WWW.DIYALARMFORUM.COM
Section 5 – Data Field Descriptions
5-7