FrameMaker Ver5.5E(PC) Di151 SWITCHES ON PWBs/TECH. REP. SETTINGS
2000.02.03
3-2.

Tech. Rep. Mode Setting Procedure

<Setting Procedure>
1. Press the following keys in this order:
Clear/Stop
Exposure Control Lighter (<)
2. Press the 1Key until the desired Tech. Rep. sub-mode is reached. Sub-modes cycle as
follows:
Display "d"
Tech. Rep. Choice "C"
3. When the code that represents the desired sub-mode is displayed, press the Start key.
<Exiting the Mode>
• Press the Clear/Stop key.
(1)

Display

• Displays the count of each of different counters and makes some checks.
• The maximum value that can be displayed for the counter is 999,999.
<Procedure>
• Press the 1Key as necessary until "d" appears on the display.
• Press the Start key to let the copier start the sequence.
<Exiting the Mode>
• Press the Clear/Stop key.
Code
Displays the count of the I/C counter.
Two digits each are displayed on the display, cycling through all digits
of the count as detailed below.
d1
E.g.: 1234
d3
Turns ON and flashes OFF and ON all LEDs on the control panel to
check for correct operation.
Displays the count of the misfeed counter.
Two digits each are displayed on the display, cycling through all digits
of the count as detailed below.
d4
E.g.: 12
Clear/Stop
Function "F"
Description
<I/C Counter>
d1
00
<LED Test>
<Misfeed Counter>
d4
00
S-11
Exposure Control Darker (>)
Adjust "A"
12
34
00
12