Adjustment Of Upper Unit Interlock Switch S2 - Minolta Di151 Service Manual

Hide thumbs Also See for Di151:
Table of Contents

Advertisement

FrameMaker Ver.5.5E(PC) Di151 DIS/REASSEMBLY, ADJUSTMENT
00.03.21
3-2.

ADJUSTMENT OF UPPER UNIT INTERLOCK SWITCH S2

1. Release and swing up the upper half of the copier and remove the Right Cover.
2. Remove the Fusing Cover.
3. Loosen the screw on the Upper Unit Interlock Switch adjusting bracket and slide it
downward until it is stops.
4. Swing down the upper half of the copier into its locked position.
5. Moving the Upper Unit Interlock Switch adjusting bracket upward, find the position at
which a click of the switch is heard. Then tighten the screw to secure the adjusting
bracket in that position.
[Check Method]
When the Power Switch is turned ON, the Exposure Lamp should turn ON.
Upper Unit Interlock Switch Adjusting Bracket
4007D039AA
D-31