5-2. Adjustment of Interlock Switch Position
When the Top cover is closed and the power supply does not come back on even
though the Power Switch (S1) is turned ON, check and adjust the position of the
Interlock Switch (S2) following the procedure below.
1. Open the top cover and remove the left cover, right cover and front cover.
2. After loosening the screw of the interlock switch (S2), close the top cover care-
fully.
3. Move the interlock switch (S2) up and down and tighten the screw at the posi-
tion where the switch turns on.
4121s082
Inter Lock Switch (S2)