15
. ELECTRICAL EQUIPMENT
wire and ground.
Measure the resistance between the resistor A
green/black wire and ground.
Resistances:
Resistor A: 9.9 10.5Ω
Resistor B: 5.6 6.2Ω
REGULATOR/RECTIFIER
INSPECTION
Remove the front cover. ( ð 12-3)
Disconnect the regulator/rectifier wire coupler
and remove the bolt to remove the
regulator/rectifier.
Measure the resistances between the terminals.
Replace the regulator/rectifier if the readings
are not within the specifications in the table
below.
Probe⊕
A (R)
B (W)
Probe(-)
A (R)
B (W)
3-10KΩ
C (Y)
D (G)
C (Y)
D (G)
33-35K
33-35K
ZX / SCOUT
50
Resister A
Resister B
Bolt
Regulator/Rectifier
Coupler
A (Red)
B (White)
C (Yellow)
D (Green)
15-6