Steps For Finalizing The Installation; Air Shutter Adjustment - Travis Industries Xtreme 6020 Installation Manual

With screen
Hide thumbs Also See for Xtreme 6020:
Table of Contents

Advertisement

Steps for Finalizing the Installation

1.
Remove the glass frame (see page 45).
2.
We recommend you purge the gas line at this time (with the glass frame removed). This allows gas to be
detected once it enters the firebox, ensuring gas does not build up.
3.
Replace the glass frame.
4.
Start the fireplace.
5.
Leak test all gas joints.
6.
Check the air shutter following the directions below.

Air Shutter Adjustment

There are three air shutters on the fireplace. We recommend you adjust the air shutters prior to installing the
crushed glass. You may wish to use an assistant to hold the glass frame while adjusting the air shutter.
a) Let the fireplace burn for three minutes.
b) Check the flame height on the three burners (left, right, and center). Each should be approximately
10" to 15" tall at the highest point. Individual flames may have a different pattern, but the overall
height should be similar from left to right (see the photo below).
NOTE: The flames will look different when the crushed glass is installed.
c) If adjustment is needed, the air shutters can be adjusted with the appliance running. Carefully open
the glass frame to access the air shutters (have a helper hold the glass frame if necessary). The air
shutters are marked with an "X" for closed (less air – more orange flame) and "0" for open (more air –
more blue flame). Tap the air shutters with the glass latch tool, taking care not to burn yourself or
ignite clothing (wear a leather glove and no sleeves). Close the glass frame and allow the fireplace
to burn for 30 seconds to assess flame height and quality.
NOTE: The right air shutter is reversed. Look for the markings on the air shutter when adjusting.
d) With the correct air shutter setting the fireplace should have a uniform flame height from left to right
with no sooting.
© Travis Industries
Installation
(for qualified installers only)
4140717
43
100-01351

Advertisement

Table of Contents
loading

This manual is also suitable for:

9850032598500326

Table of Contents