You will notice the there are multiple framing diagrams and specifications for many of the units included in this framing guide. Travis Industries has developed a means to reduce the amount of heat that is exhausted from the front of the fireplace by relocating that heat to another location. This optional accessory is referred to as the CoolSmart TV Wall™...
Page 12 564 TV 35K Heating Capacity: Up to 1,700 square feet BTU Input Per Hour: 12,000 (NG) 7,500 (LP) to 35,000 (NG/LP) Glass Viewing Area: Ceramic Glass, 29-3/8″ W x 16 3/8″ H, 479.8 Sq. In. Scan for Installation Manual 564 TV 35K - Fireplace Dimensions...
Page 21 864 TRV 31K - Framing Dimensions - Standard HINT: place the fireplace so the center line is at least 5" (127mm) from both vertical framing members at the rear (this allows the vent to pass through the framing without modfications) Vent Clearances 8"...
Page 25 864 TRV 31K CF - Framing Dimensions - Standard HINT: place the fireplace so the center line is at least 5" (127mm) from both vertical framing members at the rear (this allows the vent to pass through the framing without modfications) Vent Clearances 8"...
Page 28 864 TV 40K Heating Capacity: Up to 2,000 square feet BTU Input Per Hour: 11,000 (NG) 12,000 (LP) to 40,000 (NG/LP) Glass Viewing Area: Ceramic Glass, 34-1/4″ W x 22-1/4″ H x 2, 758.8 Sq. In. Scan for Installation Manual 864 TV 40K - Fireplace Dimensions...
Page 32 864 TV 40K CleanFace Heating Capacity: Up to 2,000 square feet BTU Input Per Hour: 11,000 (NG) 12,000 (LP) to 40,000 (NG/LP) Glass Viewing Area: Ceramic Glass, 34-1/4″ W x 22-1/4″ H x 2, 758.8 Sq. In. Scan for Installation Manual 864 TV 40K CF - Fireplace Dimensions...
Page 33 864 TV 40K CF - Framing Dimensions - Standard Max. Header Depth 3-1/2” (89mm) Min. Enclosure Height NG = 62-3/4" (1594mm) LP = 74-3/4" (1899mm) Do not build into the fireplace enclosure 45" (1143mm) IDB1031 43" (1093mm) 22" (559mm) Standard Facing (drywall contacts side of fireplace) 22-1/2"...
Page 40 3615 HO Linear Scan for Heating Capacity: Up to 1,700 Sq. Ft. Installation Manual BTU Input Per Hour: 18,331 (NG) 17,555 (LP) to 33,000 (NG/LP) Glass Viewing Area: Ceramic Glass, 34-1/8″ W x 13″ H, 440.6 Sq. In. 3615 HO - Fireplace Dimensions 210 lbs.
Page 42 3615 HO - Framing Dimension - With CoolSmart Kit 24-1/2" (674mm) 3615 CoolSmart Framing Braces for Manifold Support Brackets 3-3/4" Bottom of Upper (96mm) Manifold Framing Max. 120" 8-1/2" (3048mm) (216mm) Min. 67-1/4" (1709mm) 37-5/8" (956mm) 40-3/4" 17" (432mm) (1036mm) Flush Install * The dark-shaded framing may be installed after the fireplace is put into position.
Page 43 3615 HO - Framing Dimension - With CoolSmart Side Vent Kit * The dimension shown is the minimum depth when the manifold is installed in the typical orientation to the side of the chase (based on the width of the manifold). If installing the manifolds in an alternate location or different orientation, the chase may be framed to the fireplaces minimum framing depth (see appliance manual for details).
Page 44 4415 HO Linear Scan for Heating Capacity: Up to 2,100 Sq. Ft. Installation Manual BTU Input Per Hour: 21,672 (NG) 21,413 (LP) to 42,000 (NG/LP) Glass Viewing Area: Ceramic Glass, 42 1/8″ x 13″, 544 Sq. In. 4415 HO - Fireplace Dimensions 60"...
Page 46 4415 HO - Framing Dimension - With CoolSmart Kit 24-1/4" (616mm) Braces for Manifold Support Brackets 3-3/4" Bottom of Upper (96mm) Manifold Framing Max. 120" (3048mm) 8-1/2" (216mm) Min. 67-1/4” (1709mm) Min. 37-5/8" (956mm) 48-3/4” (1239mm) 17" (432mm) * The dark-shaded framing may be installed after the fireplace is put into position.
Page 47 4415 HO - Framing Dimension - With CoolSmart Side Vent Kit * The dimension shown is the minimum depth when the manifold is installed in the typical orientation to the side of the chase (based on the width of the manifold). If installing the manifolds in an alternate location or different orientation, the chase may be framed to the fireplaces minimum framing depth (see appliance manual for details) 17602168 - 9/23/21...
Page 48 4415 HO See-Through Linear Scan for Heating Capacity: Up to 2,100 Sq. Ft. Installation Manual BTU Input Per Hour: 21,672 (NG) 21,413 (LP) to 42,000 (NG/LP) Viewing Area: Ceramic Glass, 42 1/8″ W x 13″ H x 2 sides, 1088 Sq. In. NO COOLSMART TV WALL OPTION 4415 HO ST - Fireplace Dimensions 275 lbs.
Page 49 4415 HO ST - Framing Dimensions - Standard FRAMING WARNING: Depending upon vent configuration, framing above the fireplace may be placed flat to the wall (or notched) to allow proper clearances to the vent. Min. Enclosure Height 64” (1626mm) HINT: The shaded framing is best installed after placing the...
Page 50 6015 HO Linear Scan for Heating Capacity: Up to 2,800 Sq. Ft. Installation Manual BTU Input Per Hour: 30,273 (NG) 29,626 (LP) to 56,000 (NG/LP) Glass Viewing Area: Ceramic Glass, 58 1/8″ W x 13″ H, 751 Sq. In. 6015 HO - Fireplace Dimensions LP Min.
Page 51 6015 HO - Framing Dimensions - Standard Max. Header Depth 3-1/2” (89mm) Min. Enclosure Height 66" (1677mm) Do not build into the fireplace enclosure 66" (1677mm) Min. Enclosure Height 72” (1829mm) 72" Do not build into the (1829mm) fireplace enclosure 64-3/4"...
Page 53 6015 HO - Framing Dimension - With CoolSmart Side Vent Kit * The dimension shown is the minimum depth when the manifold is installed in the typical orientation to the side of the chase (based on the width of the manifold). If installing the manifolds in an alternate location or different orientation, the chase may be framed to the fireplaces minimum framing depth (see appliance manual for details).
Page 54 ProBuilder™ 42 Linear Scan for Heating Capacity: Up to 1,250 Sq. Ft. Installation Manual BTU/Hr. Input (NG/LP): 13,000 to 25,000 Glass Viewing Area: Tempered Glass, 40-3/8” W x 13-5/8” H, 548 Sq. In PB 42 Linear - Fireplace Dimensions 17602168 - 9/23/21...
Page 57 PB 42 Linear - Framing Dimension - With CoolSmart Side Vent Kit * The dimension shown is the minimum depth when the manifold is installed in the typical orientation to the side of the chase (based on the width of the manifold). If installing the manifolds in an alternate location or different orientation, the chase may be framed to the fireplaces minimum framing depth (see appliance manual for details).
Page 58 ProBuilder™ 54 Linear Scan for Heating Capacity: Up to 1,650 Sq. Ft. Installation Manual BTU/Hr Input (NG/LP): 17,000 to 33,000 Glass Viewing Area: Tempered Glass, 52-3/8” W x 13-5/8” H, 711 Sq. In. PB 54 Linear - Fireplace Dimensions 17602168 - 9/23/21...
Page 61 PB 54 Linear - Framing Dimension - With CoolSmart Side Vent Kit * The dimension shown is the minimum depth when the manifold is installed in the typical orientation to the side of the chase (based on the width of the manifold). If installing the manifolds in an alternate location or different orientation, the chase may be framed to the fireplaces minimum framing depth (see appliance manual for details).
Page 62 ProBuilder™ 72 Linear Scan for Heating Capacity*: Up to 2,250 Sq. Ft. Installation Manual BTU/Hr. Input (NG/LP): 23,000 to 45,000 Glass Viewing Area: Tempered Glass, 70-3/8” W x 13-5/8” H, 956 Sq. In. PB 72 Linear - Fireplace Dimensions 43"...
Page 63 PB 72 Linear - Framing Dimensions - Standard Min. Enclosure Height Max. Header Depth 68” (77mm) (1727mm) Do not build into the fireplace enclosure 43" (1092mm) 77-1/8" (1959mm) 15-7/8" (404mm) 17602168 - 9/23/21...
Page 65 PB 72 Linear - Framing Dimension - With CoolSmart Side Vent Kit * The dimension shown is the minimum depth when the manifold is installed in the typical orientation to the side of the chase (based on the width of the manifold). If installing the manifolds in an alternate location or different orientation, the chase may be framed to the fireplaces minimum framing depth (see appliance manual for details).
Page 68 PB 24CF - Framing Dimension - With CoolSmart Kit PB24CF 26-1/2" 674mm Braces for Manifold Support Brackets 3-3/4" Bottom of Upper 96mm Manifold Framing Max. 120" 3048mm 8-1/2" 216mm Min. 73-3/4" 1874mm 41-1/4" 1048mm 25-1/8" 639mm 15-1/2" 37-3/8" 950mm 394mm NOTE: The dark-shaded framing is typically installed after the manifold is installed.
Page 69 PB 24CF - Framing Dimension - With CoolSmart Side Vent Kit * The dimension shown is the minimum depth when the manifold is installed in the typical orientation to the side of the chase (based on the width of the manifold). If installing the manifolds in an alternate location or different orientation, the chase may be framed to the fireplaces minimum framing depth (see appliance manual for details).
Page 73 PB 36CF - Framing Dimension - With CoolSmart Side Vent Kit * The dimension shown is the minimum depth when the manifold is installed in the typical orientation to the side of the chase (based on the width of the manifold). If installing the manifolds in an alternate location or different orientation, the chase may be framed to the fireplaces minimum framing depth (see appliance manual for details).
Page 77 PB 42CF - Framing Dimension - With CoolSmart Side Vent Kit * The dimension shown is the minimum depth when the manifold is installed in the typical orientation to the side of the chase (based on the width of the manifold). If installing the manifolds in an alternate location or different orientation, the chase may be framed to the fireplaces minimum framing depth (see appliance manual for details).
If you have a pre-existing masonry or zero-clearance wood fireplace ask your dealer about the many gas insert options that Travis Industries offers and consult with them about what type of appliance is most appropriate for your application.