Travis Industries 564 TRV 25K Framing Manual
Hide thumbs Also See for 564 TRV 25K:
Table of Contents

Advertisement

Quick Links

Gas Fireplace
Framing Guide
NOTE: FOR GENERAL REFERENCE ONLY.
Always consult the appliance and accessory installation
manuals for detailed installation information.
Manuals are found at
www.fireplacex.com
or
by scanning the
QR codes on the following pages
Copyright © 2021 -
17602168

Advertisement

Table of Contents
loading

Summary of Contents for Travis Industries 564 TRV 25K

  • Page 1 Gas Fireplace Framing Guide NOTE: FOR GENERAL REFERENCE ONLY. Always consult the appliance and accessory installation manuals for detailed installation information. Manuals are found at www.fireplacex.com by scanning the QR codes on the following pages Copyright © 2021 - 17602168...
  • Page 2: Table Of Contents

    564 TRV 25K - Framing Dimensions - Standard ....5 3615 HO - Framing Dimension - With CoolSmart Side Vent     564 TRV 25K - Framing Dimension - With CoolSmart Kit ..6 Kit ..................43 564 TRV 25K - Framing Dimension - With CoolSmart Side  ...
  • Page 3: Why Are There Multiple Framing Specifications For The Same Unit

    You will notice the there are multiple framing diagrams and specifications for many of the units included in this framing guide. Travis Industries has developed a means to reduce the amount of heat that is exhausted from the front of the fireplace by relocating that heat to another location. This optional accessory is referred to as the CoolSmart TV Wall™...
  • Page 4: Trv 25K

    25,000 (NG/LP)  Glass Viewing Area: Tempered Glass, 29- 3/8″ W x 16 3/8″ H, 479.8 Sq. In. Scan for Installation Manual 564 TRV 25K - Fireplace Dimensions Top Vent Configuration 8" (203mm) Diameter Vent 4-3/4" Rear Vent Configuration 121mm 8"...
  • Page 5: Trv 25K - Framing Dimensions - Standard

    Page 5 564 TRV 25K - Framing Dimensions - Standard Max. 3" 77mm MIn. Enclosure 39-1/2" 1004mm 37-1/4" 947mm 37-3/4" 959mm 17-1/2" 445mm 17602168 - 9/23/21...
  • Page 6: 564 Trv 25K - Framing Dimension - With Coolsmart Kit

    Page 6 564 TRV 25K - Framing Dimension - With CoolSmart Kit 26-1/2" 674mm Braces for Manifold Support Brackets 3-3/4" Bottom of Upper 96mm Manifold Framing 8-1/2" Max. 120" 216mm 3048mm Min. 70-7/8" 1801mm 564 25K Standard 37-3/4” (959mm) 17-1/2” (445mm) 37-1/4”...
  • Page 7: Trv 25K - Framing Dimension - With Coolsmart Side Vent Kit

    Page 7 564 TRV 25K - Framing Dimension - With CoolSmart Side Vent Kit 564 25K 37-3/4” (959mm) 17-1/2” (445mm) 37-1/4” (947mm) 17602168 - 9/23/21...
  • Page 8: Trv 25K Cleanface

    25,000 (NG/LP)  Glass Viewing Area: Tempered Glass, 29-3/8″ W x 16 3/8″ H, 479.8 Sq. In. Scan for Installation Manual 564 TRV 25K CF - Fireplace Dimensions Top Vent Configuration 8" (203mm) Ø Vent 4-3/4" 121mm Rear Vent Configuration 31-3/4"...
  • Page 9: Trv 25K Cf - Framing Dimensions - Standard

    Page 9 564 TRV 25K CF - Framing Dimensions - Standard Max. 3" 77mm MIn. Enclosure 39-1/2" 1004mm 37-1/4" 947mm 38-3/4" 985mm 19-3/8" 493mm Flush Install 18-7/8" 480mm Extended (Tile Over) Install 17602168 - 9/23/21...
  • Page 10: 564 Trv 25K Cf - Framing Dimension - With Coolsmart Kit

    Page 10 564 TRV 25K CF - Framing Dimension - With CoolSmart Kit 26-1/2" 674mm Braces for Manifold Support Brackets 3-3/4" Bottom of Upper 96mm Manifold Framing 8-1/2" Max. 120" 216mm 3048mm Min. 70-7/8" 1801mm 564 25K CleanFace 38-3/4” (985mm) 19-3/8”...
  • Page 11: Trv 25K Cf - Framing Dimension - With Coolsmart Side Vent Kit

    Page 11 564 TRV 25K CF - Framing Dimension - With CoolSmart Side Vent Kit 564 25K CleanFace 38-3/4” (985mm) 19-3/8” (493mm) Flush 18-7/8” (480mm) Extended 37-1/4” (947mm) 17602168 - 9/23/21...
  • Page 12: Tv 35K

    Page 12 564 TV 35K  Heating Capacity: Up to 1,700 square feet  BTU Input Per Hour: 12,000 (NG) 7,500 (LP) to 35,000 (NG/LP)  Glass Viewing Area: Ceramic Glass, 29-3/8″ W x 16 3/8″ H, 479.8 Sq. In. Scan for Installation Manual 564 TV 35K - Fireplace Dimensions...
  • Page 13: Tv 35K - Framing Dimensions - Standard

    Page 13 564 TV 35K - Framing Dimensions - Standard Minimum Max. Header Depth Enclosure 3” (77mm) Height 58-1/4" (1480mm) 70-1/4" (1784mm) 37-1/4" (947mm) 37-3/4" (959mm) 17-1/2" (445mm) 17602168 - 9/23/21...
  • Page 14: 564 Tv 35K - Framing Dimension - With Coolsmart Kit

    Page 14 564 TV 35K - Framing Dimension - With CoolSmart Kit 26-1/2" (674mm) Braces for Manifold Support Brackets 3-3/4" Bottom of Upper (96mm) Manifold Framing Max. 120" (3048mm) 8-1/2" (216mm) Min. 76-7/8" (1953mm) 564 35K Standard 37-3/4” (959mm) 17-1/2” (445mm) 37-1/4”...
  • Page 15: Tv 35K - Framing Dimension - With Coolsmart Side Vent Kit

    Page 15 564 TV 35K - Framing Dimension - With CoolSmart Side Vent Kit 564 35K 37-3/4” (959mm) 17-1/2” (445mm) 37-1/4” (947mm) 17602168 - 9/23/21...
  • Page 16: Tv 35K Cleanface

    Page 16 564 TV 35K CleanFace  Heating Capacity: Up to 1,700 square feet  BTU Input Per Hour: 12,000 (NG) 7,500 (LP) to 35,000 (NG/LP)  Glass Viewing Area: Ceramic Glass, 29-3/8″ W x 16 3/8″ H, 479.8 Sq. In. Scan for Installation Manual 564 TV 35K CF - Fireplace Dimensions...
  • Page 17: 564 Tv 35K Cf - Framing Dimensions - Standard

    Page 17 564 TV 35K CF - Framing Dimensions - Standard Minimum Max. Header Depth Enclosure 3” (77mm) Height 58-1/4" (1480mm) 70-1/4" (1784mm) 37-1/4" (947mm) 38-3/4" (985mm) 19-3/8” (493mm) Flush Install 18-7-8” (480mm) Extended (Tile Over) Install 17602168 - 9/23/21...
  • Page 18: Tv 35K Cf - Framing Dimension - With Coolsmart Kit18

    Page 18 564 TV 35K CF - Framing Dimension - With CoolSmart Kit 26-1/2" (674mm) Braces for Manifold Support Brackets 3-3/4" Bottom of Upper (96mm) Manifold Framing Max. 120" (3048mm) 8-1/2" (216mm) Min. 76-7/8" (1953mm) 564 35K CleanFace 38-3/4” (985mm) 19-3/8”...
  • Page 19: Tv 35K Cf - Framing Dimension - With Coolsmart Side Vent Kit

    Page 19 564 TV 35K CF - Framing Dimension - With CoolSmart Side Vent Kit 564 35K CleanFace 38-3/4” (985mm) 19-3/8” (493mm) Flush 18-7/8” (480mm) Extended 37-1/4” (947mm) 17602168 - 9/23/21...
  • Page 20: Trv 31K

    Page 20 864 TRV 31K  Heating Capacity: Up to 1,400 square feet  BTU Input Per Hour: 10,000 (NG) 8,000 (LP) to 31,000 (NG/LP)  Glass Viewing Area: Tempered Glass, 34-1/4″ W x 22-1/4″ H, 758.8 Sq. In. Scan for Installation Manual 864 TRV 31K - Fireplace Dimensions Top Vent Configuration...
  • Page 21: Trv 31K - Framing Dimensions - Standard

    Page 21 864 TRV 31K - Framing Dimensions - Standard HINT: place the fireplace so the center line is at least 5" (127mm) from both vertical framing members at the rear (this allows the vent to pass through the framing without modfications) Vent Clearances 8"...
  • Page 22: 864 Trv 31K - Framing Dimension - With Coolsmart Kit

    Page 22 864 TRV 31K - Framing Dimension - With CoolSmart Kit 24-1/4" 616mm Braces for Manifold Support Brackets 3-3/4" Bottom of Upper 96mm Manifold Framing 8-1/2" Max. 120" 216mm 3048mm Min. 77" 1956mm 864 31K 43-1/2” (1105mm) 20-3/4” (528mm) 38-1/2”...
  • Page 23: Trv 31K - Framing Dimension - With Coolsmart Side Vent Kit

    Page 23 864 TRV 31K - Framing Dimension - With CoolSmart Side Vent Kit 864 31K 41-1/4” (1048mm) 20-3/4” (528mm) 38-1/2” (978mm) 17602168 - 9/23/21...
  • Page 24: Trv 31K Cleanface

    Page 24 864 TRV 31K CleanFace  Heating Capacity: Up to 1,400 square feet  BTU Input Per Hour: 10,000 (NG) 8,000 (LP) to 31,000 (NG/LP)  Glass Viewing Area: Tempered Glass, 34-1/4″ W x 22-1/4″ H x 2, 758.8 Sq. In. Scan for Installation Manual 864 TRV 31K CF - Fireplace Dimensions...
  • Page 25: 864 Trv 31K Cf - Framing Dimensions - Standard

    Page 25 864 TRV 31K CF - Framing Dimensions - Standard HINT: place the fireplace so the center line is at least 5" (127mm) from both vertical framing members at the rear (this allows the vent to pass through the framing without modfications) Vent Clearances 8"...
  • Page 26: 864 Trv 31K Cf - Framing Dimension - With Coolsmart Kit

    Page 26 864 TRV 31K CF - Framing Dimension - With CoolSmart Kit 24-1/4" 616mm Braces for Manifold Support Brackets 3-3/4" Bottom of Upper 96mm Manifold Framing 8-1/2" Max. 120" 216mm 3048mm Min. 77" 1956mm 864 31K CF 43-1/2” (1105mm) 22-1/2”...
  • Page 27: Trv 31K Cf -Framing Dimension - With Coolsmart Side Vent Kit

    Page 27 864 TRV 31K CF -Framing Dimension - With CoolSmart Side Vent Kit 864 31K CleanFace 43” (1093mm) 22-1/2” (572mm) 45” (1143mm) 17602168 - 9/23/21...
  • Page 28: Tv 40K

    Page 28 864 TV 40K  Heating Capacity: Up to 2,000 square feet  BTU Input Per Hour: 11,000 (NG) 12,000 (LP) to 40,000 (NG/LP)  Glass Viewing Area: Ceramic Glass, 34-1/4″ W x 22-1/4″ H x 2, 758.8 Sq. In. Scan for Installation Manual 864 TV 40K - Fireplace Dimensions...
  • Page 29: Tv 40K - Framing Dimensions - Standard

    Page 29 864 TV 40K - Framing Dimensions - Standard IDB1254 Max. Header Depth 3-1/2” (89mm) Min. Enclosure Height NG = 62-3/4" (1594mm) LP = 74-3/4" (1899mm) Do not build into the fireplace enclosure 38-1/2" (978mm) 41-1/4" (1048mm) 20-3/4" (528mm) 17602168 - 9/23/21...
  • Page 30: 864 Tv 40K - Framing Dimension - With Coolsmart Kit

    Page 30 864 TV 40K - Framing Dimension - With CoolSmart Kit 24-1/4" 616mm Braces for Manifold Support Brackets 3-3/4" Bottom of Upper 96mm Manifold Framing 8-1/2" Max. 120" 216mm 3048mm Min. 77" 1956mm 864 40K 43-1/2” (1105mm) 20-3/4” (528mm) 38-1/2”...
  • Page 31: Tv 40K - Framing Dimension - With Coolsmart Side Vent Kit

    Page 31 864 TV 40K - Framing Dimension - With CoolSmart Side Vent Kit 864 40K 41-1/4” (1048mm) 20-3/4” (528mm) 38-1/2” (978mm) 17602168 - 9/23/21...
  • Page 32: Tv 40K Cleanface

    Page 32 864 TV 40K CleanFace  Heating Capacity: Up to 2,000 square feet  BTU Input Per Hour: 11,000 (NG) 12,000 (LP) to 40,000 (NG/LP)  Glass Viewing Area: Ceramic Glass, 34-1/4″ W x 22-1/4″ H x 2, 758.8 Sq. In. Scan for Installation Manual 864 TV 40K CF - Fireplace Dimensions...
  • Page 33: 864 Tv 40K Cf - Framing Dimensions - Standard

    Page 33 864 TV 40K CF - Framing Dimensions - Standard Max. Header Depth 3-1/2” (89mm) Min. Enclosure Height NG = 62-3/4" (1594mm) LP = 74-3/4" (1899mm) Do not build into the fireplace enclosure 45" (1143mm) IDB1031 43" (1093mm) 22" (559mm) Standard Facing (drywall contacts side of fireplace) 22-1/2"...
  • Page 34: Tv 40K Cf - Framing Dimension - With Coolsmart Kit34

    Page 34 864 TV 40K CF - Framing Dimension - With CoolSmart Kit 24-1/4" 616mm Braces for Manifold Support Brackets 3-3/4" Bottom of Upper 96mm Manifold Framing 8-1/2" Max. 120" 216mm 3048mm Min. 77" 1956mm 864 40K CleanFace 43-1/2” (1105mm) 22-1/2”...
  • Page 35: Tv 40K Cf - Framing Dimension - With Coolsmart Side Vent Kit

    Page 35 864 TV 40K CF - Framing Dimension - With CoolSmart Side Vent Kit 864 40K CleanFace 43” (1093mm) 22-1/2” (572mm) 45” (1143mm) 17602168 - 9/23/21...
  • Page 36: 4237 Eg

    Page 36 4237 EG  Heating Capacity: Up to 3,000 square feet  BTU Input Per Hour: 14,500 (NG) 13,600 (LP) to 60,000 (NG/LP)  Glass Viewing Area: Ceramic Glass, 39-7/8″ W x 34-7/8″ H, 1388 Sq. In. Scan for Installation Manual 4237 EG - Fireplace Dimensions 17602168 - 9/23/21...
  • Page 37: 4237 Tv - Framing Dimensions - Standard

    Page 37 4237 EG - Framing Dimensions - Standard 17602168 - 9/23/21...
  • Page 38: 4237 Eg - Framing Dimension - With Coolsmart Kit

    Page 38 4237 EG - Framing Dimension - With CoolSmart Kit 17602168 - 9/23/21...
  • Page 39: 4237 Eg - Framing Dimension - With Coolsmart Side Vent Kit

    Page 39 4237 EG - Framing Dimension - With CoolSmart Side Vent Kit 17602168 - 9/23/21...
  • Page 40: 3615 Ho Linear

    Page 40 3615 HO Linear Scan for  Heating Capacity: Up to 1,700 Sq. Ft. Installation Manual  BTU Input Per Hour: 18,331 (NG) 17,555 (LP) to 33,000 (NG/LP)  Glass Viewing Area: Ceramic Glass, 34-1/8″ W x 13″ H, 440.6 Sq. In. 3615 HO - Fireplace Dimensions 210 lbs.
  • Page 41: 3615 Ho - Framing Dimensions - Standard

    Page 41 3615 HO - Framing Dimensions - Standard Max. Header Depth 3-1/2” (89mm) IDB1246 Min. Enclosure Height 54" (1372mm) Do not build into the fireplace enclosure 54" (1372mm) 40-3/4" (1036mm) 17" (432mm) Flush Install 17602168 - 9/23/21...
  • Page 42: 3615 Ho - Framing Dimension - With Coolsmart Kit

    Page 42 3615 HO - Framing Dimension - With CoolSmart Kit 24-1/2" (674mm) 3615 CoolSmart Framing Braces for Manifold Support Brackets 3-3/4" Bottom of Upper (96mm) Manifold Framing Max. 120" 8-1/2" (3048mm) (216mm) Min. 67-1/4" (1709mm) 37-5/8" (956mm) 40-3/4" 17" (432mm) (1036mm) Flush Install * The dark-shaded framing may be installed after the fireplace is put into position.
  • Page 43: 3615 Ho - Framing Dimension - With Coolsmart Side Vent Kit

    Page 43 3615 HO - Framing Dimension - With CoolSmart Side Vent Kit * The dimension shown is the minimum depth when the manifold is installed in the typical orientation to the side of the chase (based on the width of the manifold). If installing the manifolds in an alternate location or different orientation, the chase may be framed to the fireplaces minimum framing depth (see appliance manual for details).
  • Page 44: 4415 Ho Linear

    Page 44 4415 HO Linear Scan for  Heating Capacity: Up to 2,100 Sq. Ft. Installation Manual  BTU Input Per Hour: 21,672 (NG) 21,413 (LP) to 42,000 (NG/LP)  Glass Viewing Area: Ceramic Glass, 42 1/8″ x 13″, 544 Sq. In. 4415 HO - Fireplace Dimensions 60"...
  • Page 45: 4415 Ho - Framing Dimensions - Standard

    Page 45 4415 HO - Framing Dimensions - Standard Max. Header Depth 3-1/2” IDB1248 (89mm) Min. Enclosure Height 60" (1524mm) 60" (1524mm) 48-3/4" (1239mm) 17" (432mm) 17602168 - 9/23/21...
  • Page 46: 4415 Ho - Framing Dimension - With Coolsmart Kit

    Page 46 4415 HO - Framing Dimension - With CoolSmart Kit 24-1/4" (616mm) Braces for Manifold Support Brackets 3-3/4" Bottom of Upper (96mm) Manifold Framing Max. 120" (3048mm) 8-1/2" (216mm) Min. 67-1/4” (1709mm) Min. 37-5/8" (956mm) 48-3/4” (1239mm) 17" (432mm) * The dark-shaded framing may be installed after the fireplace is put into position.
  • Page 47: 4415 Ho - Framing Dimension - With Coolsmart Side Vent Kit

    Page 47 4415 HO - Framing Dimension - With CoolSmart Side Vent Kit * The dimension shown is the minimum depth when the manifold is installed in the typical orientation to the side of the chase (based on the width of the manifold). If installing the manifolds in an alternate location or different orientation, the chase may be framed to the fireplaces minimum framing depth (see appliance manual for details) 17602168 - 9/23/21...
  • Page 48: 4415 Ho See-Through Linear

    Page 48 4415 HO See-Through Linear Scan for  Heating Capacity: Up to 2,100 Sq. Ft. Installation Manual  BTU Input Per Hour: 21,672 (NG) 21,413 (LP) to 42,000 (NG/LP)  Viewing Area: Ceramic Glass, 42 1/8″ W x 13″ H x 2 sides, 1088 Sq. In. NO COOLSMART TV WALL OPTION 4415 HO ST - Fireplace Dimensions 275 lbs.
  • Page 49: 4415 Ho St - Framing Dimensions - Standard

    Page 49 4415 HO ST - Framing Dimensions - Standard FRAMING WARNING: Depending upon vent configuration, framing above the fireplace may be placed flat to the wall (or notched) to allow proper clearances to the vent. Min. Enclosure Height 64” (1626mm) HINT: The shaded framing is best installed after placing the...
  • Page 50: 6015 Ho Linear

    Page 50 6015 HO Linear  Scan for Heating Capacity: Up to 2,800 Sq. Ft. Installation Manual  BTU Input Per Hour: 30,273 (NG) 29,626 (LP) to 56,000 (NG/LP)  Glass Viewing Area: Ceramic Glass, 58 1/8″ W x 13″ H, 751 Sq. In. 6015 HO - Fireplace Dimensions LP Min.
  • Page 51: 6015 Ho - Framing Dimensions - Standard

    Page 51 6015 HO - Framing Dimensions - Standard Max. Header Depth 3-1/2” (89mm) Min. Enclosure Height 66" (1677mm) Do not build into the fireplace enclosure 66" (1677mm) Min. Enclosure Height 72” (1829mm) 72" Do not build into the (1829mm) fireplace enclosure 64-3/4"...
  • Page 52: 6015 Ho - Framing Dimension - With Coolsmart Kit

    Page 52 6015 HO - Framing Dimension - With CoolSmart Kit 34" (864mm) Braces for Manifold 3-3/4" Support Brackets (96mm) Bottom of Upper Manifold Framing Max. 120" (3048mm) 8-1/2" Min. 67-1/4" (1709mm) (216mm) Min. 37-5/8" * (950mm) * 64-3/4" * (1645mm) * 77-1/8"...
  • Page 53: 6015 Ho - Framing Dimension - With Coolsmart Side Vent Kit

    Page 53 6015 HO - Framing Dimension - With CoolSmart Side Vent Kit * The dimension shown is the minimum depth when the manifold is installed in the typical orientation to the side of the chase (based on the width of the manifold). If installing the manifolds in an alternate location or different orientation, the chase may be framed to the fireplaces minimum framing depth (see appliance manual for details).
  • Page 54: Probuilder™ 42 Linear

    Page 54 ProBuilder™ 42 Linear Scan for  Heating Capacity: Up to 1,250 Sq. Ft. Installation Manual  BTU/Hr. Input (NG/LP): 13,000 to 25,000  Glass Viewing Area: Tempered Glass, 40-3/8” W x 13-5/8” H, 548 Sq. In PB 42 Linear - Fireplace Dimensions 17602168 - 9/23/21...
  • Page 55: Pb 42 Linear - Framing Dimensions - Standard

    Page 55 PB 42 Linear - Framing Dimensions - Standard 17602168 - 9/23/21...
  • Page 56: Pb 42 Linear - Framing Dimension - With Coolsmart Kit

    Page 56 PB 42 Linear - Framing Dimension - With CoolSmart Kit 72, 54 PB Linear 34"(864mm) 42 PB Linear 28" (712mm) Braces for Manifold 3-3/4" Support Brackets 96mm Bottom of Upper Manifold Framing Max. 120" 3048mm 8-1/2" Min. 66-1/2" 216mm 1690mm 34-1/2"...
  • Page 57: Pb 42 Linear - Framing Dimension - With Coolsmart Side Vent Kit

    Page 57 PB 42 Linear - Framing Dimension - With CoolSmart Side Vent Kit * The dimension shown is the minimum depth when the manifold is installed in the typical orientation to the side of the chase (based on the width of the manifold). If installing the manifolds in an alternate location or different orientation, the chase may be framed to the fireplaces minimum framing depth (see appliance manual for details).
  • Page 58: Probuilder™ 54 Linear

    Page 58 ProBuilder™ 54 Linear Scan for  Heating Capacity: Up to 1,650 Sq. Ft. Installation Manual  BTU/Hr Input (NG/LP): 17,000 to 33,000  Glass Viewing Area: Tempered Glass, 52-3/8” W x 13-5/8” H, 711 Sq. In. PB 54 Linear - Fireplace Dimensions 17602168 - 9/23/21...
  • Page 59: Pb 54 Linear - Framing Dimensions - Standard

    Page 59 PB 54 Linear - Framing Dimensions - Standard 17602168 - 9/23/21...
  • Page 60: Pb 54 Linear - Framing Dimension - With Coolsmart Kit

    Page 60 PB 54 Linear - Framing Dimension - With CoolSmart Kit 72, 54 PB Linear 34"(864mm) 42 PB Linear 28" (712mm) Braces for Manifold 3-3/4" Support Brackets 96mm Bottom of Upper Manifold Framing Max. 120" 3048mm 8-1/2" Min. 66-1/2" 216mm 1690mm 34-1/2"...
  • Page 61: Pb 54 Linear - Framing Dimension - With Coolsmart Side Vent Kit

    Page 61 PB 54 Linear - Framing Dimension - With CoolSmart Side Vent Kit * The dimension shown is the minimum depth when the manifold is installed in the typical orientation to the side of the chase (based on the width of the manifold). If installing the manifolds in an alternate location or different orientation, the chase may be framed to the fireplaces minimum framing depth (see appliance manual for details).
  • Page 62: Probuilder™ 72 Linear

    Page 62 ProBuilder™ 72 Linear Scan for  Heating Capacity*: Up to 2,250 Sq. Ft. Installation Manual  BTU/Hr. Input (NG/LP): 23,000 to 45,000  Glass Viewing Area: Tempered Glass, 70-3/8” W x 13-5/8” H, 956 Sq. In. PB 72 Linear - Fireplace Dimensions 43"...
  • Page 63: Pb 72 Linear - Framing Dimensions - Standard

    Page 63 PB 72 Linear - Framing Dimensions - Standard Min. Enclosure Height Max. Header Depth 68” (77mm) (1727mm) Do not build into the fireplace enclosure 43" (1092mm) 77-1/8" (1959mm) 15-7/8" (404mm) 17602168 - 9/23/21...
  • Page 64: Pb 72 Linear - Framing Dimension - With Coolsmart Kit

    Page 64 PB 72 Linear - Framing Dimension - With CoolSmart Kit 72, 54 PB Linear 34"(864mm) 34” (864mm) 42 PB Linear 28" (712mm) Braces for Manifold 3-3/4" Support Brackets 96mm Bottom of Upper Manifold Framing Max. 120" 3048mm 8-1/2" Min.
  • Page 65: Pb 72 Linear - Framing Dimension - With Coolsmart Side Vent Kit

    Page 65 PB 72 Linear - Framing Dimension - With CoolSmart Side Vent Kit * The dimension shown is the minimum depth when the manifold is installed in the typical orientation to the side of the chase (based on the width of the manifold). If installing the manifolds in an alternate location or different orientation, the chase may be framed to the fireplaces minimum framing depth (see appliance manual for details).
  • Page 66: Probuilder 24Cf

    Page 66 ProBuilder 24CF  Heating Capacity: Up to 750 Sq. Ft.  BTU Input Per Hour: 9,500 (NG/LP) to 18,000 (NG/LP)  Glass Viewing Area: Tempered Glass, 18” W x 26” H, 466.9 sq. in. Scan for Installation Manual PB 24CF - Fireplace Dimensions 12-3/8"...
  • Page 67: Pb 24Cf - Framing Dimensions - Standard

    Page 67 PB 24CF - Framing Dimensions - Standard Max. Header Depth 3” (77mm) Min. Enclosure Height 53" (1347mm) 41-1/4" (1048mm) 25-1/8" 15-1/2" (639mm) (394mm) 17602168 - 9/23/21...
  • Page 68: Pb 24Cf - Framing Dimension - With Coolsmart Kit

    Page 68 PB 24CF - Framing Dimension - With CoolSmart Kit PB24CF 26-1/2" 674mm Braces for Manifold Support Brackets 3-3/4" Bottom of Upper 96mm Manifold Framing Max. 120" 3048mm 8-1/2" 216mm Min. 73-3/4" 1874mm 41-1/4" 1048mm 25-1/8" 639mm 15-1/2" 37-3/8" 950mm 394mm NOTE: The dark-shaded framing is typically installed after the manifold is installed.
  • Page 69: Pb 24Cf - Framing Dimension - With Coolsmart Side Vent Kit

    Page 69 PB 24CF - Framing Dimension - With CoolSmart Side Vent Kit * The dimension shown is the minimum depth when the manifold is installed in the typical orientation to the side of the chase (based on the width of the manifold). If installing the manifolds in an alternate location or different orientation, the chase may be framed to the fireplaces minimum framing depth (see appliance manual for details).
  • Page 70: Probuilder 36Cf

    Page 70 ProBuilder 36CF  Heating Capacity: Up to 1,150 Sq. Ft.  MV & GSB Versions - BTU Input Per Hour: 13,000 (NG) 12,000 (LP) to 25,000 (NG) 24,000 (LP)  Deluxe Version - BTU Input Per Hour: 5,000 (NG) 6,000 (LP) to 25,000 (NG) 24,000 (LP) ...
  • Page 71: Pb 36Cf - Framing Dimensions - Standard

    Page 71 PB 36CF - Framing Dimensions - Standard Max. Header Depth (77mm) 3” Min. Enclosure Height 61-7/8" (1572mm) 41" (1042mm) 37-1/8" (943mm) 15-3/4" (401mm) 17602168 - 9/23/21...
  • Page 72: Pb 36Cf - Framing Dimension - With Coolsmart Kit

    Page 72 PB 36CF - Framing Dimension - With CoolSmart Kit 26-1/2" 674mm PB36CF Braces for Manifold Support Brackets 3-3/4" Bottom of Upper 96mm Manifold Framing Max. 120" 8-1/2" 3048mm 216mm Min. 73-3/4" 1874mm 41" 1042mm 37-3/8" 950mm 15-1/4" 388mm 17602168 - 9/23/21...
  • Page 73: Pb 36Cf - Framing Dimension - With Coolsmart Side Vent Kit

    Page 73 PB 36CF - Framing Dimension - With CoolSmart Side Vent Kit * The dimension shown is the minimum depth when the manifold is installed in the typical orientation to the side of the chase (based on the width of the manifold). If installing the manifolds in an alternate location or different orientation, the chase may be framed to the fireplaces minimum framing depth (see appliance manual for details).
  • Page 74: Probuilder 42Cf

    Page 74 ProBuilder 42CF  Heating Capacity: Up to 1,750 Sq. Ft.  MV & GSB Versions - BTU Input Per Hour: 18,000 (NG) 17,500 (LP) to 35,000 (NG/LP)  Deluxe Version - BTU Input Per Hour: 8,000 (NG) 7,500 (LP) to 35,000 (NG/LP) ...
  • Page 75: Pb 42Cf - Framing Dimensions - Standard

    Page 75 PB 42CF - Framing Dimensions - Standard Max. Header Depth 3” (77mm) Min. Enclosure Height 68" (1728mm) 46-1/4" (1175mm) 43" (1093mm) 17-1/4" (439mm) 17602168 - 9/23/21...
  • Page 76: Pb 42Cf - Framing Dimension - With Coolsmart Kit

    Page 76 PB 42CF - Framing Dimension - With CoolSmart Kit PB42CF 24-1/4" 616mm Braces for Manifold Support Brackets 3-3/4" Bottom of Upper 96mm Manifold Framing 8-1/2" Max. 120" 216mm 3048mm Min. 78-3/4" 2001mm 46-1/4" 1175mm 43" 1093mm 17-1/4" 439mm 17602168 - 9/23/21...
  • Page 77: Pb 42Cf - Framing Dimension - With Coolsmart Side Vent Kit

    Page 77 PB 42CF - Framing Dimension - With CoolSmart Side Vent Kit * The dimension shown is the minimum depth when the manifold is installed in the typical orientation to the side of the chase (based on the width of the manifold). If installing the manifolds in an alternate location or different orientation, the chase may be framed to the fireplaces minimum framing depth (see appliance manual for details).
  • Page 78: Gas Fireplace Installation Worksheet

    If you have a pre-existing masonry or zero-clearance wood fireplace ask your dealer about the many gas insert options that Travis Industries offers and consult with them about what type of appliance is most appropriate for your application.