Electrical Connection - Travis Industries Xtreme 6020 Installation Manual

With screen
Hide thumbs Also See for Xtreme 6020:
Table of Contents

Advertisement

Electrical Connection

The electrical line to the grounded receptacle inside the fireplace must be installed by a qualified
installer and must meet all local codes.
Make sure the household breaker is shut off prior to working on any electrical lines.
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1.
The electrical line must supply 120 Volts, 60 Hz, and minimum 5.7 Amps.
Route the electrical connection through the zc cover plate and junction box cover plate and attach to
the hookup wires pictured below.
Caution:
Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation.
Hot
(black)
Common
(white)
Ground
(green)
© Travis Industries
Installation
(for qualified installers only)
Romex
Clamp
Black
White
Green
Exhaust Damper Wire Harness
4140717
Receptacles
Electrical Hookup Wires
(labeled 120VAC IN)
Exhaust Blower Wires
21
100-01351

Advertisement

Table of Contents
loading

This manual is also suitable for:

9850032598500326

Table of Contents