22
Wiring the Exhaust Blower
Do not connect 110-120 VAC to the gas control valve or wiring system of this fireplace.
The exhaust box is wired to the 120v line exiting the exhaust blower rheostat. Connect a minimum 12
gauge sheathed three-wire electrical line from the rheostat to the exhaust blower junction box. Attach
the wires as shown below.
Test blower operation after attaching the wiring (leave gas off, turn appliance on, verify blower
functions correctly).
Fireplace Junction Box
Black
White
Green
Molex (installed in
fireplace)
Remove the cover plate on the exhaust blower
housing.
Route the electrical line through the romex
connector and attach the 120v wiring as detailed in
the wiring diagram.
© Travis Industries
Installation
Black
White
Green
Romex
Clamp
(for qualified installers only)
Capacitor
Black
Exhaust Blower Junction Box
4140717
Black
Red
Black
White
Green
100-01351