Electrical Connection (required)

The electrical line to the junction box inside the fireplace must be installed by a qualified installer and
must meet all local codes.
Make sure the household breaker is shut off prior to working on any electrical lines.
The appliance, when installed, must be electrically grounded in accordance with local codes.
The electrical line must be a min. 14 gauge, and supply 240 Volts at 50 Hz (2 Amps)
Caution:
Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation.
Junction Box Assembly
Grounded 240V Power Supply
(Insulate wire ends)
© Travis Industries
Installation
(for qualified installers only)
Left Side of Fireplace
Strain Relief
4070620
19
100-01199_000